Flag displaying the general status of the blocks
It is the individual information showing the operating status of the resisted lists of the high speed link
parameters. It displays the status of high speed link by registered lists up to 64 like the maximum
number of registrations. It displays the general information for the registered lists by synthesizing
individual information of each item. When the transmission · reception status of the relevant list is normal
and the operation mode is RUN with no error, it will be ‘On’; when the above items are violated, it will be
‘Off’.
(4)
RUN operating mode flag of the block station
It is the individual information showing the operating status of the resisted lists of the high speed link
parameters. It displays the operating mode information by registered lists up to 64 like the maximum
number of registrations. When the station of the registered items is under Run mode, the relevant bit will
be ‘On’; when the station is under Stop/Pause/Debug mode, it will be ‘Off’.
(5)
Flag displaying the block station and normal communication
It is the individual information showing the operating status of the resisted lists of the high speed link
parameters. It displays the transmission · reception information of the registered list up to 64. When the
transmission · reception operation works based on the cycle, the relevant bit will be ‘On’; when the
operation does not work normally, it will be ‘Off’.
(6)
Operation error mode flag of the block station
It is the individual information showing the operating status of the resisted lists of the high speed link
parameters. It displays the error information of the registered list up to 64 the maximum number of
registrations. The error synthetically indicates the situation that the PLC cannot execute the user
programs normally. When it is Off, it means the opposing station’s PLC works normally; when it is On, it
means the opposing station is abnormal.
Содержание XBE-DC08A
Страница 124: ...Main Chapter 1 Configuration and Operation Mode of Programs 1 27 1 Memory block diagram ...
Страница 155: ...Main Chapter 2 CPU Function 2 29 Notice For more details on the monitor refer to the XG5000 manual ...
Страница 504: ...Position Chap 6 Commands 6 61 6 11 Function blocks related to Servo Drive ...
Страница 512: ...Positioning Chapter 7 Program 7 8 manual operation 7 1 4 Parameter and Operation Data Setting 1 Parameter Setting ...
Страница 644: ...Positioning Chapter 8 Functions 8 91 ...
Страница 727: ...Positioning Chapter 9 Positioning Error Information Solutions 9 13 ...
Страница 861: ...Special Chapter 1 Embedded Analog 1 39 5 Select View Variables Comments Variables and comments are both displayed ...
Страница 1206: ...Appendix 2 Dimension App2 1 Appendix 2 Dimension Unit mm 1 CPU Type XEC DN32U 2 Positioning Type XEC DN32UP ...
Страница 1207: ...Appendix 2 Dimension App2 2 2 Analog Type XEC DN32UA ...
Страница 1209: ...Appendix 2 Dimension App2 4 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Страница 1210: ...Appendix 2 Dimension App2 5 4 Extension Cnet I F Module XBL C41A XBL C21A ...