Po
sit
io
n
in
g
Chapter 4 Positioning Parameter & Operation Data
4-9
(2)
Infinite running repeat position
(a) When using “Infinite running repeat” mode, it sets the repeated position value.
(b) This is applied when “Infinite running repeat” in the extended parameter is “1: Enable”. When this parameter setting
value is “0: Disable”, command position and current position is expressed within position expression range according
to value set in “Unit” of basic parameter.
(c) When “Infinite running repeat” parameter is “1: enable”, command position and current position is expressed as 0 ~
“infinite running repeat position-1”.
(d) Setting range
Unit
Infinite running repeat position range
pulse
1
∼
2,147,483,647[pulse]
㎜
1
∼
2,147,483,647[X10
-4
㎜
]
Inch
1
∼
2,147,483,647[X10
-5
Inch]
degree
1
∼
2,147,483,647[X10
-5
degree]
(3)
Infinite running repeat
(a) It sets whether to enable or disable “Infinite running repeat”
(b) When you set “Infinite running repeat” as “1: enable”, command position and current position refreshes within the
range set in “Infinite running repeat position” periodically.
(c) When you don’t use “Infinite running repeat” function, set as “0: disable”.
(4)
Backlash Compensation Amount
(a) In case that a gear, screw etc is combined to the motor axis, The tolerance that the machine does not work by the
wear, when the rotation direction changes, is called as ‘Backlash”. Therefore, when you change the rotation
direction, it is required to add the backlash compensation amount to the positioning amount for output.
(b) This is used for positioning operation, inching operation and jog operation
(c) Setting range
Unit
Backlash setting range
pulse
0
∼
65,535[pulse]
㎜
0
∼
65,535[X10
-4
㎜
]
Inch
0
∼
65,535[X10
-5
Inch]
degree
0
∼
65,535[X10
-5
degree]
Infinite running
repeat position
Содержание XBE-DC08A
Страница 124: ...Main Chapter 1 Configuration and Operation Mode of Programs 1 27 1 Memory block diagram ...
Страница 155: ...Main Chapter 2 CPU Function 2 29 Notice For more details on the monitor refer to the XG5000 manual ...
Страница 504: ...Position Chap 6 Commands 6 61 6 11 Function blocks related to Servo Drive ...
Страница 512: ...Positioning Chapter 7 Program 7 8 manual operation 7 1 4 Parameter and Operation Data Setting 1 Parameter Setting ...
Страница 644: ...Positioning Chapter 8 Functions 8 91 ...
Страница 727: ...Positioning Chapter 9 Positioning Error Information Solutions 9 13 ...
Страница 861: ...Special Chapter 1 Embedded Analog 1 39 5 Select View Variables Comments Variables and comments are both displayed ...
Страница 1206: ...Appendix 2 Dimension App2 1 Appendix 2 Dimension Unit mm 1 CPU Type XEC DN32U 2 Positioning Type XEC DN32UP ...
Страница 1207: ...Appendix 2 Dimension App2 2 2 Analog Type XEC DN32UA ...
Страница 1209: ...Appendix 2 Dimension App2 4 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Страница 1210: ...Appendix 2 Dimension App2 5 4 Extension Cnet I F Module XBL C41A XBL C21A ...