Chapter 8 Functions
8-127
8.5.2 Continuous Operation
Execute positioning control changing the current operation step no. to the next one.
(1) Characteristics of Control
(a) When continuous operation command is executed, operating speed is changed into the speed of next operation step
directly.
(b) This command may be used in End, Go on, Continuous mode and used at Acc.,Dec.,Steady speed section.
(c) If continuous operation command is executed in operation, the current operation step no. is changed to the next step no.
and keep operating.
(d) There are differences of operation depending on between absolute coordinates and relative coordinates.
(2) Operation timing
B
Time
ON
Speed
Start
In operation
In operation
ON
Operation mode:
Singular, End
Step no. : 2
Operation mode :
Singular, Continuous
Step no. : 1
Position P1
Time
Speed
ON
ON
Time
ON
Speed
Start
Continuous
operation
command
In operation
In operation
ON
Operation mode:
Singular, End
Step no. : 2
Operation mode :
Singular, Continuous
Step no. : 1
Time
Speed
ON
ON
A
Position P2
Position P1
Position P2
Position P1
Position
P1+P2
Position P1
Position
P1+P2
Continuous
operation
command
Operation mode:
Singular, End
Step no. : 2
Operation mode:
Singular, End
Step no. : 2
Operation mode :
Singular, Continuous
Step no. : 1
Operation mode :
Singular, Continuous
Step no. : 1
Operation on absolute coordinates
Operation on relative coordinates
N
o
t
U
s
e
C
o
n
in
u
o
u
s
O
p
e
ra
t
U
s
e
C
o
n
ti
n
u
o
u
s
O
p
e
ra
ti
o
n
■ The goal positions of continuous operation on absolute coordinates are same, so the goal position is the same as the
position before and after continuous operation. Therefore, the current position positioned by continuous operation is P2. (A
area and B area both are same size)
■ When continuous operation is executed on relative coordinates, the movement amount between current position and goal
position is the real goal position. Therefore, the goal position is different from the one without continuous operation. The
position positioned by continuous operation is P1 + P2.
Содержание XBE-DC08A
Страница 124: ...Main Chapter 1 Configuration and Operation Mode of Programs 1 27 1 Memory block diagram ...
Страница 155: ...Main Chapter 2 CPU Function 2 29 Notice For more details on the monitor refer to the XG5000 manual ...
Страница 504: ...Position Chap 6 Commands 6 61 6 11 Function blocks related to Servo Drive ...
Страница 512: ...Positioning Chapter 7 Program 7 8 manual operation 7 1 4 Parameter and Operation Data Setting 1 Parameter Setting ...
Страница 644: ...Positioning Chapter 8 Functions 8 91 ...
Страница 727: ...Positioning Chapter 9 Positioning Error Information Solutions 9 13 ...
Страница 861: ...Special Chapter 1 Embedded Analog 1 39 5 Select View Variables Comments Variables and comments are both displayed ...
Страница 1206: ...Appendix 2 Dimension App2 1 Appendix 2 Dimension Unit mm 1 CPU Type XEC DN32U 2 Positioning Type XEC DN32UP ...
Страница 1207: ...Appendix 2 Dimension App2 2 2 Analog Type XEC DN32UA ...
Страница 1209: ...Appendix 2 Dimension App2 4 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Страница 1210: ...Appendix 2 Dimension App2 5 4 Extension Cnet I F Module XBL C41A XBL C21A ...