P
o
sit
io
n
in
g
Chapter 7 Program
7-22
(d) Ready signal for each axis
According to exercise from “Chapter 7.1.2 Current State Reading,” it is a signal of “Drive Ready” for each axis. This
command only works when this is the condition for Drive Ready is on. If it is not set as “ON,” the “error 295” would be
appeared.
(e) Address of Positioning Module
In this example, Positioning Module is fixed at the 1 slot of 0 bases.
(f) Axis for Synchronous Start
Set axis for Synchronous Start. The axis for Synchronous Start uses a “bit” from WORD Data setting as a “1” for each
axis. Axis for each bits are as below.
15~4 Bit
3Bit
2Bit
1Bit
0Bit
N/A
Axis 4
Axis 3
Axis 2
Axis1
(g) Synchronous start step no. per each axis
Set the step no. of each axis for synchronous start. UP type can control 4 axes, it doesn’t use A4_STEP ~ A8_STEP
input.
(h) State of Operation complete
If function block is completed without error, “1” will be outputted and maintain “1” until the next operation. If error
occurred, “0” will be outputted.
(i) Error State
This is the area that output error no. if there are errors in operation of function block.
(j) The function block used in the example is as follows.
Axis1_2 Synchronous start : Execute no.10 operation step of axis1 and step of %MW170(axis2 synchronous start
step) synchronously.
.
Содержание XBE-DC08A
Страница 124: ...Main Chapter 1 Configuration and Operation Mode of Programs 1 27 1 Memory block diagram ...
Страница 155: ...Main Chapter 2 CPU Function 2 29 Notice For more details on the monitor refer to the XG5000 manual ...
Страница 504: ...Position Chap 6 Commands 6 61 6 11 Function blocks related to Servo Drive ...
Страница 512: ...Positioning Chapter 7 Program 7 8 manual operation 7 1 4 Parameter and Operation Data Setting 1 Parameter Setting ...
Страница 644: ...Positioning Chapter 8 Functions 8 91 ...
Страница 727: ...Positioning Chapter 9 Positioning Error Information Solutions 9 13 ...
Страница 861: ...Special Chapter 1 Embedded Analog 1 39 5 Select View Variables Comments Variables and comments are both displayed ...
Страница 1206: ...Appendix 2 Dimension App2 1 Appendix 2 Dimension Unit mm 1 CPU Type XEC DN32U 2 Positioning Type XEC DN32UP ...
Страница 1207: ...Appendix 2 Dimension App2 2 2 Analog Type XEC DN32UA ...
Страница 1209: ...Appendix 2 Dimension App2 4 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Страница 1210: ...Appendix 2 Dimension App2 5 4 Extension Cnet I F Module XBL C41A XBL C21A ...