Chapter 4 Built-in High-speed Counter Function
4-11
(3) Compared output
(a) High Speed counter module has a compared output function used to compare present count value with
compared value in size to output as compared.
(b) Available compared outputs are 2 for 1 channel, which can be used separately.
(c) Compared output conditions are 7 associated with >, =, < .
(d) Parameter setting
• Comp. output mode setting
• Upper setting value is saved in special K area.
Compared output condition
Memory address (word)
Value
*2)
Comp output 0
Comp output 1
Present Value < Compared Value
Ch.0 %KW302
Ch.1 %KW 332
Ch.2 %KW 362
Ch.3 %KW 392
Ch.4 %KW 2222
Ch.5 %KW 2252
Ch.6 %KW 2282
Ch.7 %KW 2312
Ch.0 %KW 303
Ch.1 %KW 333
Ch.2 %KW 363
Ch.3 %KW 393
Ch.4 %KW 2223
Ch.5 %KW 2253
Ch.6 %KW 2283
Ch.7 %KW 2313
Set to “0”
Present Value ≤ Compared Value
Set to “1”
Present Value = Compared Value
Set to “2”
Present Value ≥ Compared Value
Set to “3”
Present Value > Compared Value
Set to “4”
Compared value 1 ≤ Count value ≤ Compared value 2
Set to “5”
Count value
≤
Compared value 1
,
Count value
≥
Compared value 2
Set to “6”
*2)
If compared output mode set value is other than 0~6 at using counter, error code ‘23’ occurs.
Содержание XBE-DC08A
Страница 124: ...Main Chapter 1 Configuration and Operation Mode of Programs 1 27 1 Memory block diagram ...
Страница 155: ...Main Chapter 2 CPU Function 2 29 Notice For more details on the monitor refer to the XG5000 manual ...
Страница 504: ...Position Chap 6 Commands 6 61 6 11 Function blocks related to Servo Drive ...
Страница 512: ...Positioning Chapter 7 Program 7 8 manual operation 7 1 4 Parameter and Operation Data Setting 1 Parameter Setting ...
Страница 644: ...Positioning Chapter 8 Functions 8 91 ...
Страница 727: ...Positioning Chapter 9 Positioning Error Information Solutions 9 13 ...
Страница 861: ...Special Chapter 1 Embedded Analog 1 39 5 Select View Variables Comments Variables and comments are both displayed ...
Страница 1206: ...Appendix 2 Dimension App2 1 Appendix 2 Dimension Unit mm 1 CPU Type XEC DN32U 2 Positioning Type XEC DN32UP ...
Страница 1207: ...Appendix 2 Dimension App2 2 2 Analog Type XEC DN32UA ...
Страница 1209: ...Appendix 2 Dimension App2 4 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Страница 1210: ...Appendix 2 Dimension App2 5 4 Extension Cnet I F Module XBL C41A XBL C21A ...