B
asi
s
Chapter 4 Built-in High-speed Counter Function
4-25
4.3.2 Error code
It describes errors of the built-in high-speed counter.
• Error occurred is saved in the following area.
Category
Device area per channel
Remark
Ch0
Ch1
Ch2
Ch3
Ch4
Ch5
Ch6
Ch7
Error code
%KW266
%KW276
%KW286
%KW296
%KW2186 %KW2196 %KW2206 %KW2216
Word
▪ Error codes and descriptions
Error code
(Decimal)
Description
20
Counter type is set out of range
21
Pulse input type is set out of range
22
Requesting #1(3,)channel Run during the operation of #0(2) channel 2 phase(
* During #0(2) channel 2 phase inputting, using #1(3)channel is not possible.
23
Compared output type setting is set out of range.
25
Internal preset value is set out of counter range
26
External present value is set out of counter range
27
Ring counter setting is set out of range
* Note ring counter setting should be 2 and more.
28
Compared output min. value is set out of permissible max. input range
29
Compared output max. value is set out of permissible max. input range
30
Error of Compared output min. value>Compared output max. value
31
Compared output is set out of the default output value
34
Set value of Unit time is out of the range
35
Pulse value per 1 revolution is set out of range
36
Compared output min. value is set out of permissible max. input range (Comp. output 1)
37
Compared output max. value is set out of permissible max. input range (Comp. output 1)
38
Error of Compared output min. value>Compared output max. value (Comp. output 1)
39
Compared output is set out of the default output value (Comp. output 1)
40
Frequency measurement cycle setting error
Remark
If two and more errors occur, the module displays the latest error code.
Содержание XBE-DC08A
Страница 124: ...Main Chapter 1 Configuration and Operation Mode of Programs 1 27 1 Memory block diagram ...
Страница 155: ...Main Chapter 2 CPU Function 2 29 Notice For more details on the monitor refer to the XG5000 manual ...
Страница 504: ...Position Chap 6 Commands 6 61 6 11 Function blocks related to Servo Drive ...
Страница 512: ...Positioning Chapter 7 Program 7 8 manual operation 7 1 4 Parameter and Operation Data Setting 1 Parameter Setting ...
Страница 644: ...Positioning Chapter 8 Functions 8 91 ...
Страница 727: ...Positioning Chapter 9 Positioning Error Information Solutions 9 13 ...
Страница 861: ...Special Chapter 1 Embedded Analog 1 39 5 Select View Variables Comments Variables and comments are both displayed ...
Страница 1206: ...Appendix 2 Dimension App2 1 Appendix 2 Dimension Unit mm 1 CPU Type XEC DN32U 2 Positioning Type XEC DN32UP ...
Страница 1207: ...Appendix 2 Dimension App2 2 2 Analog Type XEC DN32UA ...
Страница 1209: ...Appendix 2 Dimension App2 4 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Страница 1210: ...Appendix 2 Dimension App2 5 4 Extension Cnet I F Module XBL C41A XBL C21A ...