Chapter 2 Built-in Cnet communication
2-54
B
u
ilt
-in
C
omm
2.5.2
Detail of instruction
1) Individual reading of device (R(r)SS)
This is a function that reads PLC device specified in accord with memory data type. Separate device memory can be
read up to 16 at a time.
PC request format
Format
name
Header
Station
No.
Comman
d
Command type
Number
of blocks
Device
length
Device name
....
Tail
Frame
check
Ex. of
frame
ENQ
H20
R(r)
SS
H01
H06
%MW100
EOT
BCC
ASCII
value
H05
H323
0
H52(72)
H5353
H3031
H3036
H254D57313030
H04
Item
Description
BCC
When command is lowercase(r), only one lower byte of the value resulted by adding 1 Byte
each to ASCII values from ENQ to EOT is converted into ASCII and added to BCC. For
example, the BCC of the above frame is gotten as below:
H05+H32+H30+H72+H53+H53+H30+H31+H30+H36+H25+H4D+H57+H31+H30+H30+H04
= H03A4 Therefore BCC value is A4 (ASCII value : H4134).
Number of
Blocks
This specifies how much of the blocks composed of "[device length][device name]" are in this
request format. This can be set up to 16. Therefore, the value of [Number of blocks] must be
set between H01(ASCII value:3031)-H10(ASCII value:3030).
Device length
(Length of
device name)
This indicates the number of name's characters that means device, which is allowable up to 16
characters. This value is one of ASCII converted from hex type, and the range is from
H01(ASCII value:3031) to H10(ASCII value:3130). For example, if the device name is %MW0,
it has 4 characters to be H04 as its length. If %MW000 characters to be H06.
Device name
Address to be actually read is entered. This must be ASCII value within 16 characters, and in
this name, digits, upper/lower case, '%' is only allowable to be entered.
•
BCC value is low 1byte in the sum of each byte from ENQ to EOT.
•
In case of making actual frame, 'H' is not attached. Because the number data of frame indicates
hexadecimal.
1
block
(
setting can be repeated up to max. 16 blocks
)
Note
Содержание XBE-DC08A
Страница 124: ...Main Chapter 1 Configuration and Operation Mode of Programs 1 27 1 Memory block diagram ...
Страница 155: ...Main Chapter 2 CPU Function 2 29 Notice For more details on the monitor refer to the XG5000 manual ...
Страница 504: ...Position Chap 6 Commands 6 61 6 11 Function blocks related to Servo Drive ...
Страница 512: ...Positioning Chapter 7 Program 7 8 manual operation 7 1 4 Parameter and Operation Data Setting 1 Parameter Setting ...
Страница 644: ...Positioning Chapter 8 Functions 8 91 ...
Страница 727: ...Positioning Chapter 9 Positioning Error Information Solutions 9 13 ...
Страница 861: ...Special Chapter 1 Embedded Analog 1 39 5 Select View Variables Comments Variables and comments are both displayed ...
Страница 1206: ...Appendix 2 Dimension App2 1 Appendix 2 Dimension Unit mm 1 CPU Type XEC DN32U 2 Positioning Type XEC DN32UP ...
Страница 1207: ...Appendix 2 Dimension App2 2 2 Analog Type XEC DN32UA ...
Страница 1209: ...Appendix 2 Dimension App2 4 XBE DC08A XBE DC16A XBE TN08A XBE TN16A XBE DR16A XBE RY08A ...
Страница 1210: ...Appendix 2 Dimension App2 5 4 Extension Cnet I F Module XBL C41A XBL C21A ...