8.7 Message List
164
Measurement Value Memory Function
:MEMory?
No Data/ ALL
Query of measurement values saved to mem-
ory by the measurement value memory func-
tion
*1,2,6
:MEMory:CLEar
Deleting data from memory of measurement
value memory function
*2
:MEMory:COUNt?
Query of number of measurement values
saved to memory by the measurement value
memory function
*1, 2
:MEMory:CONTrol
ON/ IN/ OFF
Setting of measurement value memory func-
tion
*2, 3
:MEMory:CONTrol?
Query of measurement value memory func-
tion
*1, 2
:MEMory:POINts
1 to 32000
Setting of memory size for measurement val-
ue memory function
*2, 3
:MEMory:POINts?
Query of memory size for measurement value
memory function
*1, 2
Monitor
:MONItor?
Query of voltage and current monitor levels
*1, 2
:MONItor:DISPlay
ON/ OFF
Setting of voltage and current monitor value
display
*2, 3
:MONItor:DISPlay?
Query of voltage and current monitor value
display
*1, 2
Initialize Device
:PRESet
Initialize Device
*2
Measurement Range
:RANGe
1 to 10 (NR1)
Setting of measurement range
*2, 3
:RANGe?
Query of measurement range
*1, 2
:RANGe:AUTO
ON/ OFF
Automatic setting of measurement range
*2,3,5
Unique Commands
Command
Data Section
Explanation
Error
Refer-
ence
Page
Error Explanations (An error is generated when a message is executed in the following cases)
*1 Query Error _______ When a response message exceeds 10 kB
*2 Execution Error ____ When a command is executed while open circuit, short circuit, or load compensation
*3 Execution Error ____ When set to other than the specified character data or numeric data.
*4 Execution Error ____When a number that has not been saved is specified.
*5 Execution Error ____When a command is executed during comparator measurement or BIN measure-
ment.
*6 Execution Error ____When not even one measurement value is saved to memory.
*7 Execution Error ____When there is an RS-232C specific command or query while the interface type is set
to GP-IB.
*8 Execution Error ____When a command to display a reference value in the SUB display area is executed
while the count setting is configured.
Note: Command errors are generated for all messages with a misspelling.
Содержание 3504-40 C HiTester
Страница 2: ......
Страница 22: ...1 4 Names and Functions of Parts 16 ...
Страница 28: ...2 5 Turning the Power On and Off 22 ...
Страница 40: ...3 3 Setting the Measurement Conditions 34 OF UF Evaluation Flow Chart ...
Страница 66: ...4 4 Self Calibration 60 ...
Страница 96: ...5 2 BIN Measurement Function Model 3504 50 3504 60 only 90 ...
Страница 136: ...7 4 About Measurement Times 130 ...
Страница 279: ...Appendix 5 External View Appendix A7 Appendix 5 External View Unit mm 220 3 260 1 100 1 32 5 25 21 54 20 5 95 5 15 ...
Страница 286: ...Appendix 7 Initial Settings Table A14 ...
Страница 289: ......
Страница 290: ......
Страница 291: ......
Страница 292: ......