Appendix 7 Initial Settings Table
Appe
nd
ix
A11
Factory default settings are as follows.
*1 Measurement conditions for initial value are signal level: 1 V, range: 6 and self calibration: OFF.
Appendix 7 Initial Settings Table
Yes: Available/
:
The same as the left
/
No: Unavailable
Setting Items
Initial
Setting
Operate
from
Front
Panel
:PRE-
Set
RST
Return to Ini-
tial Settings
when Power
is Turned On
Sav
e
Back
Up
Measurement
Signal
Frequency
1 kHz
No
Yes Yes
Signal Level
1 V
No
Yes Yes
Measurement
Range
Switch
AUTO
No
Yes Yes
Range
1
No
Yes Yes
Equivalent Circuit
Mode
Switch
AUTO
No
Yes Yes
Mode
Par(parallel)
No
Yes Yes
Measurement Speed
NORM
No
Yes Yes
Average
ON/ OFF
ON
No
Yes Yes
Number of Times
1
No
Yes Yes
Trigger
Mode
lnt(Internal)
No
Yes Yes
Delay
ON/ OFF
ON
No
Yes Yes
Time
0.0s
No
Yes Yes
Trigger Synchro-
nous Function
ON/ OFF
OFF
No
Yes Yes
Wait Time
120 Hz
10 ms
No
Yes Yes
1 MHz
2 ms
No
Yes Yes
Open Circuit
Compensation
Compensation Value Compensa-
tion of G
0S
No
Change
No
Change
0S
No
Yes Yes
Compensa-
tion of B
0S
No
Change
No
Change
0S
No
Yes Yes
Parameter Type
ZPH
No
Change
No
Change
ZPH
No
Yes Yes
Open Compensation Conditions
All enabled
No
No Yes
Short Circuit
Compensation
Compensation Value Compensa-
tion of R
0
No
Change
No
Change
0
No
Yes Yes
Compensa-
tion of X
0
No
Change
No
Change
0
No
Yes Yes
Parameter Type
ZPH
No
Change
No
Change
ZPH
No
Yes Yes
Short Compensation Conditions
All enabled
No
No Yes
Load Circuit
Compensation *1
Compensation Value Impedance
Coefficient
1
No
Change
No
Change
1
No
Yes Yes
Phase
Coefficient
0
No
Change
No
Change
0
No
Yes Yes
Parameter Type
COEF
No
Change
No
Change COEF
No
Yes Yes
Reference Value
Reference
Value of C
100000
No
Change
No
Change 100000
No
Yes Yes
Reference
Value of D
0
No
Change
No
Change
0
No
Yes Yes
Offset Circuit
Compensation
ON/OFF
OFF
No
Change
No
Change
OFF
No
Yes Yes
Compensation Value Compensa-
tion Value of C
0
No
Change
No
Change
0
No
Yes Yes
Compensa-
tion Value of D
0
No
Change
No
Change
0
No
Yes Yes
Содержание 3504-40 C HiTester
Страница 2: ......
Страница 22: ...1 4 Names and Functions of Parts 16 ...
Страница 28: ...2 5 Turning the Power On and Off 22 ...
Страница 40: ...3 3 Setting the Measurement Conditions 34 OF UF Evaluation Flow Chart ...
Страница 66: ...4 4 Self Calibration 60 ...
Страница 96: ...5 2 BIN Measurement Function Model 3504 50 3504 60 only 90 ...
Страница 136: ...7 4 About Measurement Times 130 ...
Страница 279: ...Appendix 5 External View Appendix A7 Appendix 5 External View Unit mm 220 3 260 1 100 1 32 5 25 21 54 20 5 95 5 15 ...
Страница 286: ...Appendix 7 Initial Settings Table A14 ...
Страница 289: ......
Страница 290: ......
Страница 291: ......
Страница 292: ......