8.7 Message List
159
8
:CORRection:OPEN?
Query of open circuit compensation function
*1, 2
:CORRection:OPEN:DATA
<compensation values
1>,<compensation val-
ues 2>
<compensation values 1>,
<compensation values 2>
= -99.9999E9 to
99.9999E9 (NR3)
Setting of open circuit compensation values
*1, 2
:CORRection:OPEN:DATA?
Query of open circuit compensation values
*1, 2
:CORRection:OPEN:DATA
:FORMat
ZPH/ GB/ CPG
Setting of output parameter for open circuit
compensation values
*2, 3
:CORRection:OPEN:DATA
:FORMat?
Query of output parameter for open circuit
compensation values
*1, 2
:CORRection:OPEN:POINt
1 to 255 (NR1)
Setting of open circuit compensation reading *2, 3
:CORRection:OPEN:POINt?
Query of open circuit compensation reading
*1, 2
:CORRection:SHORt
ALL/ ON/ OFF/ RETurn
Setting of short circuit compensation function *2, 3
:CORRection:SHORt?
Query of short circuit compensation function
*1, 2
:CORRection:SHORt:DATA
<compensation values
1>,<compensation val-
ues 2>
<compensation values
1>,<compensation values
2>
= -99.9999E9 to
99.9999E9 (NR3)
Setting of short circuit compensation values
*2, 3
:CORRection:SHORt:DATA?
Query of short circuit compensation values
*1, 2
:CORRection:SHORt:DATA
:FORMat
ZPH/ RSX/ LSRS
Setting of output parameter for short circuit
compensation values
*2, 3
:CORRection:SHORt:DATA
:FORMat?
Query of output parameter for short circuit
compensation values
*1, 2
:CORRection:SHORt:POINt
1 to 255 (NR1)
Setting of short circuit compensation reading *2, 3
:CORRection:SHORt:POINt?
Query of short circuit compensation reading
*1, 2
Load Compensation
:CORRection:LOAD
ON/ OFF/ RETurn
Setting of load compensation function
*2, 3
Unique Commands
Command
Data Section
Explanation
Error
Refer-
ence
Page
Error Explanations (An error is generated when a message is executed in the following cases)
*1 Query Error _______ When a response message exceeds 10 kB
*2 Execution Error ____ When a command is executed while open circuit, short circuit, or load compensation
*3 Execution Error ____ When set to other than the specified character data or numeric data.
*4 Execution Error ____When a number that has not been saved is specified.
*5 Execution Error ____When a command is executed during comparator measurement or BIN measure-
ment.
*6 Execution Error ____When not even one measurement value is saved to memory.
*7 Execution Error ____When there is an RS-232C specific command or query while the interface type is set
to GP-IB.
*8 Execution Error ____When a command to display a reference value in the SUB display area is executed
while the count setting is configured.
Note: Command errors are generated for all messages with a misspelling.
Содержание 3504-40 C HiTester
Страница 2: ......
Страница 22: ...1 4 Names and Functions of Parts 16 ...
Страница 28: ...2 5 Turning the Power On and Off 22 ...
Страница 40: ...3 3 Setting the Measurement Conditions 34 OF UF Evaluation Flow Chart ...
Страница 66: ...4 4 Self Calibration 60 ...
Страница 96: ...5 2 BIN Measurement Function Model 3504 50 3504 60 only 90 ...
Страница 136: ...7 4 About Measurement Times 130 ...
Страница 279: ...Appendix 5 External View Appendix A7 Appendix 5 External View Unit mm 220 3 260 1 100 1 32 5 25 21 54 20 5 95 5 15 ...
Страница 286: ...Appendix 7 Initial Settings Table A14 ...
Страница 289: ......
Страница 290: ......
Страница 291: ......
Страница 292: ......