3
Accuracy
We define measurement tolerances in terms of rdg. (reading) and dgt. (digit) val-
ues, with the following meanings:
Measurement categories
To ensure safe operation of measurement instruments, IEC 61010 estab-
lishes safety standards for various electrical environments, categorized as
CAT II to CAT IV, and called measurement categories.
CAT II: Primary electrical circuits in equipment connected to an AC electrical
outlet by a power cord (portable tools, household appliances, etc.)
CAT II covers directly measuring electrical outlet receptacles.
CAT III:Primary electrical circuits of heavy equipment (fixed installations) con-
nected directly to the distribution panel, and feeders from the distribu-
tion panel to outlets.
CAT IV:The circuit from the service drop to the service entrance, and to the
power meter and primary overcurrent protection device (distribution
panel).
Using a measurement instrument in an environment designated with a
higher-numbered category than that for which the instrument is rated could
result in a severe accident, and must be carefully avoided.
Use of a measurement instrument that is not CAT-rated in CAT II to CAT IV
measurement applications could result in a severe accident, and must be
carefully avoided.
Other Symbols
Indicates a prohibited action.
See
Indicates the location of reference information.
Indicates quick references for operation and remedies for
troubleshooting.
*
Indicates that descriptive information is provided below.
rdg.
(reading or displayed value)
The value currently being measured and
indicated on the measuring unit.
dgt. (resolution)
The smallest displayable unit on a digital
measuring unit/ device/ product, i.e., the
input value that causes the digital display
to show a "1" as the least-significant digit.
Содержание 3504-40 C HiTester
Страница 2: ......
Страница 22: ...1 4 Names and Functions of Parts 16 ...
Страница 28: ...2 5 Turning the Power On and Off 22 ...
Страница 40: ...3 3 Setting the Measurement Conditions 34 OF UF Evaluation Flow Chart ...
Страница 66: ...4 4 Self Calibration 60 ...
Страница 96: ...5 2 BIN Measurement Function Model 3504 50 3504 60 only 90 ...
Страница 136: ...7 4 About Measurement Times 130 ...
Страница 279: ...Appendix 5 External View Appendix A7 Appendix 5 External View Unit mm 220 3 260 1 100 1 32 5 25 21 54 20 5 95 5 15 ...
Страница 286: ...Appendix 7 Initial Settings Table A14 ...
Страница 289: ......
Страница 290: ......
Страница 291: ......
Страница 292: ......