8.2 Specifications
133
8
Control during
Sending
When using hardware (RTS/CTS control):
When CB(CTS) is confirmed to be OFF, the sending of data is halted. When it is
confirmed to be ON, the sending of data is resumed.
When using software (XON/XOFF control):
When XOFF is received, the sending of data is halted. When XON is received,
the sending of data is resumed.
Interface Functions _____________________________________________
Code used: ASCII code
CA(RTS)
OFF
ON
25%
85%
Input Buffer
Usage Amount
Buffer Space
75%
Send XOFF
Send XON
8.2.2 GP-IB Specifications
(Only for Models 3504-50, 3504-60)
SH1
Supports all source handshake functions.
AH1
Supports all acceptor handshake functions.
T6
Supports standard talker functions.
Supports serial poll functions.
Talk only mode is not supported.
Supports the talker cancel function by MLA (My Listen Address).
L4
Supports standard listener functions.
Listener only mode is not supported.
Supports the listener cancel function by MTA (My Talk Address).
SR1
Supports all service request functions.
RL1
Supports all remote/local functions
PP0
Parallel poll functions are not supported.
DC1
Supports all device clear functions.
DT1
Supports all device trigger functions.
C0
Controller functions are not supported.
Содержание 3504-40 C HiTester
Страница 2: ......
Страница 22: ...1 4 Names and Functions of Parts 16 ...
Страница 28: ...2 5 Turning the Power On and Off 22 ...
Страница 40: ...3 3 Setting the Measurement Conditions 34 OF UF Evaluation Flow Chart ...
Страница 66: ...4 4 Self Calibration 60 ...
Страница 96: ...5 2 BIN Measurement Function Model 3504 50 3504 60 only 90 ...
Страница 136: ...7 4 About Measurement Times 130 ...
Страница 279: ...Appendix 5 External View Appendix A7 Appendix 5 External View Unit mm 220 3 260 1 100 1 32 5 25 21 54 20 5 95 5 15 ...
Страница 286: ...Appendix 7 Initial Settings Table A14 ...
Страница 289: ......
Страница 290: ......
Страница 291: ......
Страница 292: ......