background image

Instructions for use

KEY Laser III 1243

Always be on the safe side.

Содержание KEY Laser III 1243

Страница 1: ...Instructions for use KEY Laser III 1243 Always be on the safe side...

Страница 2: ...Sales KaVo Dental GmbH Bismarckring 39 D 88400 Biberach Tel 49 7351 56 0 Fax 49 7351 56 1488 Manufacturer Kaltenbach Voigt GmbH Bismarckring 39 D 88400 Biberach www kavo com...

Страница 3: ...protection 16 2 3 4 Safety of the construction 16 2 3 5 Electromagnetic compatibility 16 2 4 Safe laser range 18 2 4 1 Warning lamps 18 2 4 2 Warning signs 19 2 5 Electromagnetic Transmissions 20 2 5...

Страница 4: ...m menu 60 4 13 4 Deleting a program 60 4 14 Changing a program setting 61 4 14 1 Reset new settings 61 4 14 2 Pilot jet setting 61 4 15 Handpiece selection 63 4 16 New program 64 4 16 1 Saving a new p...

Страница 5: ...Faults 90 8 4 Troubleshooting 91 9 Assembly notes 93 9 1 Characteristics of the floor 93 9 2 Media 94 9 2 1 Spray water 94 9 2 2 Spray air 94 9 3 Electrical connection 95 9 3 1 Local 95 9 3 2 230V ver...

Страница 6: ...cal effects of laser radiation on tissue safety conside rations effects on the eye and treatment instructions are described in a separate application manual 1 1 3 Indications and Contraindikations tre...

Страница 7: ...mote filling adherence of com posites in cavities or dental areas which have been treated by KEY Laser or rotating instruments None known Sealing Fissures Sealing of non carious molars and pre molars...

Страница 8: ...too far into the alveola ridge or the marginal gingiva and influencing function phonetics and denture fit tings etc None known Apicectomy Apicectomy on teeth with periapical lesion which had not resp...

Страница 9: ...ive installation The use of incorrect information Improper use Improper installation startup and repairs The KEY Lasers 1243 may only be installed repaired and serviced by technicians who have success...

Страница 10: ...sposal service providers and recycling companies please visit the following In ternet sites http www umweltdatenbank de http www quality de KaVo will bring KaVo transport packaging returned by the cus...

Страница 11: ...ries of members for collection points for used polystyrene packaging and cartons were passed on in 1991 by KaVo to the dental trade in connection with the above mentioned customer information sheet Fo...

Страница 12: ...product serial number in all requests Additional information can be obtained at www kavo com To ensure that the KEY Laser 1243 is always ready for use and maintains its value the recommended maintenan...

Страница 13: ...tes a maximum hazardous situation that can directly cause serious injury or death 2 1 2 Hazard levels DANGER indicates the maximum hazard level indicates a directly hazardous situ ation that can cause...

Страница 14: ...he respectively valid version of the regulations of German professional associations on safety BGV for laser radiation BGV B2 must also be observed Accessories by other manufacturers may not be used N...

Страница 15: ...ions adjustments modifications or repairs are performed by Service Technicians who have successfully completed the KEY Laser 1243 trai ning A laser safety officer must be appointed The electrical inst...

Страница 16: ...embolism and skin emphysema The insufflation of spray in open wounds in the surgical area can cause air embo lisms and skin emphysema Avoid the insufflation of spray in open wounds in surgical area C...

Страница 17: ...keit von Herzschritt machern in der zahn rztlichen Praxis Discussion of Machtens On the influence of pacemakers in dental practice Dtsch zahn rztl Z 42 11 16 1987 Aderhold L J Kreuzer Diskussionsbeitr...

Страница 18: ...l not be directly aware of many of these measures Directly after turning the device on the microprocessor control will run a self check Then a series of safety relevant components will be operated and...

Страница 19: ...with the exception of transformers and lines that KaVo sells as replacement parts for inter nal components can increase transmission or reduce the electromagnetic immu nity of the product Only use acc...

Страница 20: ...a e B r e s a L Warning lamps Warning signs 2 4 1 Warning lamps In the planning stage make sure that warning lights are installed at all entrance doors to the treatment rooms in which the KEY Laser 1...

Страница 21: ...Warning signs The current warning signs are to be affixed at eye height to the entrance doors to the treatment room in which the KEY Laser 1243 is used and be visible from the outside Note The warning...

Страница 22: ...i delines HF transmissions according to CISPR 11 Group 1 The KEY Laser 1243 uses HF ener gy only for its internal operation Its HF transmission is therefore very low and it is improbable that neigh bo...

Страница 23: ...1 kV normal mode volta ge 2 kV common mode voltage 1 kV push pull voltage 2 kV common mode volta ge The quality of the supply voltage should correspond to that of a typical business or hospital enviro...

Страница 24: ...00 MHz the higher frequency range applies NOTE 2 These guidelines may not be applicable in every case The spread of electromagnetic waves is absorbed and reflected by buildings objects and people a Th...

Страница 25: ...Instructions for use KEY Laser III 1243 2 Safety 2 5 Electromagnetic Transmissions d Within the frequency range of 150 kHz to 80 MHz the field strength should be less than 3V eff V m 23 99...

Страница 26: ...on the transmission fre quence in m Rated power of the trans mitter in W 150 kHz to 80 MHz d 1 17 P 80 MHz to 800 MHz d 0 35 P 800 MHz to 2 5 GHz d 0 70 P 0 01 0 12 0 04 0 07 0 1 0 37 0 11 0 22 1 1 1...

Страница 27: ...er 1243 material no 1 000 5342 3 Description of Instrument 3 1 KEY Laser 1243 material no 1 000 5342 Laser tubing Key switch on off function Swing arm Emergency laser stop Laser emission indicator Han...

Страница 28: ...Laser III 1243 3 Description of Instrument 3 1 KEY Laser 1243 material no 1 000 5342 3 1 1 Multifunction foot control Tread protection hoop Energy setting Ready button Laser pulse trigger Frequency se...

Страница 29: ...Instructions for use KEY Laser III 1243 3 Description of Instrument 3 1 KEY Laser 1243 material no 1 000 5342 3 1 2 Back of the laser unit 27 99...

Страница 30: ...door contact max 24 V 1 A switch contact for external warning lamp Do not connect external voltage with the door contact Version B 100 V 110 V 120 V 127 V 50 Hz 60 Hz Mains input fuse 25 A Japan 20 A...

Страница 31: ...KEY Laser III 1243 3 Description of Instrument 3 2 Touch screen 3 2 Touch screen The central control is a touchscreen i e a screen whose surface is used actively for controlling functions by touching...

Страница 32: ...umber with Year of manufacture YYYY Running serial number REF Material number DAB Mode of continuous operation with duty type Classification of application part type B 5333 IEC 417 Note observe accomp...

Страница 33: ...of Instrument 3 4 Where to affix the laser warning signs and laser note 3 4 Where to affix the laser warning signs and laser note On the back of the laser unit there is a triangle warning sign and th...

Страница 34: ...III 1243 3 Description of Instrument 3 4 Where to affix the laser warning signs and laser note A triangular laser warning symbol and information notice is also mounted at the laser tube coupling Lase...

Страница 35: ...100 127 V 25 A Customer fuse protection 100 127 V Japan 20 A Classification Device of protection class 1 Device not protected against the penet ration of water Type B application part Operating condit...

Страница 36: ...00 700 s Divergence Divergence of the laser beam after exi ting the laser contra angle hand piece 2060 Mat no 1 000 4841 approx 5 10 NOHD 1 m Pilot laser Laser type Red laser diode Laser class 2 max 1...

Страница 37: ...ax 5 V 10 mA load on the door con tact Switching contact for external warning lamp max 24 V 1A Packaging transportation and storage Gross weight 93 kg Net weight 81 kg Packaging dimensions 1100 x 600...

Страница 38: ...operation In unclear or dangerous situations the laser can be immediately switched off com pletely by pressing the switch Note However the emergency laser stop should not be used for switching off no...

Страница 39: ...the unit Unscrew the spray water reservoir bottle in a clockwise direction Fill spray water reservoir bottle Note The spray water reservoir bottle may be filled only with distilled or demineralized w...

Страница 40: ...ngs are not knocked against anything and are never laid down roughly Ensure that the exit window of the exit coupling is not soiled or contaminated with fingerprints This may damage the coa ting and t...

Страница 41: ...rotective caps and Push handpiece axially so that it will go onto the laser coupling until it is heard to snap in Note Before the treatment the spray should be set and a user test performed See also 4...

Страница 42: ...h the handpiece To avoid contamination of the tube coupling window wipe the tube coupling from back to front using a clean dry cloth See also Section A 2 3 of handpiece instructions Note Windows are c...

Страница 43: ...Instructions for use KEY Laser III 1243 4 Operation 4 3 Laser tube handpieces Dry the inside of the handpiece coupling 41 99...

Страница 44: ...as pressed it springs out Switch on main switch on the back of the unit Insert key into key operated switch By turning the key completely clockwise switch on the KEY Laser 1243 US After a few seconds...

Страница 45: ...unit to stand unattended in the switched on state See also 4 19 Switch off Page 71 4 4 1 Energy saving mode If no operation is performed on the KEY Laser 1243 US for a period of 5 mintues the unit swi...

Страница 46: ...s under a numerical value make it possible to change this value inc reases reduces the value in accordance with a preset scale Once the minimum or maximum value is reached the arrow key disappears and...

Страница 47: ...lot laser emerges at the front of the handpiece Only in this state is it possible to emit laser pulses 4 6 1 Triggering laser pulses A priority logic switch which detects the position of the swing arm...

Страница 48: ...the handpiece should be placed on the handpiece support The KEY Laser 1243 automatically switches from the ready mode to the standby mode if no operation of a control touchscreen footswitch handpiece...

Страница 49: ...e g 160 mJ The pulse energy levels can be regulated with the arrow keys and Alternatively the pulse energy can also be set via the foot switch by pressing the button Note If the pulse energy is change...

Страница 50: ...Instructions for use KEY Laser III 1243 4 Operation 4 7 Setting pulse energy and pulse frequency Alternatively the pulse frequency can also be set via the foot switch by pressing the button 48 99...

Страница 51: ...6 Ready mode Page 45 Point the handpiece at a cotton wool ball or swab moistened with water If the pilot laser is visibly poor broken up or completely invisible the laser exit wind ow is probably soil...

Страница 52: ...malgam and composite fillings can also change the fluorescence signal Detection and feedback modes use the fluorescent radiation emitted by altered tooth substance on exposure to a specific light wave...

Страница 53: ...th detection mode and feedback mode are switched off No information appears in the region between frequency data and mode key Note The laser can be operated under this setting but without the feedback...

Страница 54: ...function of the laser beam When the laser pulse trigger is pressed in the ready mode laser pulses are triggered only when as a result of the detection an altered tooth substance is found i e when the...

Страница 55: ...numerical display shows the currently saved threshold value When the Threshold value key is pressed the threshold value menu opens When the arrow key is pressed the threshold value increases by one va...

Страница 56: ...Instructions for use KEY Laser III 1243 4 Operation 4 10 Threshold setting In the start menu the saved threshold value is now displayed 54 99...

Страница 57: ...user chooses between the spray settings AIR_and WATER The two keys function according to the on off principle Off Dark key with bright inscription On Bright key with dark inscription AIR and WATER ca...

Страница 58: ...without accepting the changed spray setting 4 11 2 Foot control The chosen spray medium can be switched on and off using the spray key of the foot switch 4 11 3 Spray test By pressing the spray key 1...

Страница 59: ...wing settings can be entered the sound volume for the key tone the noise level of the detection signal the language of the touchscreen resetting of the changed programs for default values Setting the...

Страница 60: ...EY Laser III 1243 4 Operation 4 12 System menu Note After the end of the language selection using the OK key all texts including the predefined programs are reloaded This means that a program reset is...

Страница 61: ...ouchscreen When the program selection key is pressed the program selection menu opens 4 13 2 Program selection menu Max 6 lines can be displayed in the selection menu overview The selection bar is mov...

Страница 62: ...stem menu The system menu dialogue can be called up by pressing the system menu key See also 4 12 System menu Page 57 4 13 4 Deleting a program The predefined programs cannot be deleted Only programs...

Страница 63: ...n be saved under the existing program name by pressing the OK key To save the changes with a new name use the save key to save it as a new program See also 4 16 New program Page 64 The AIR and WATER k...

Страница 64: ...etting In the feedback or detection mode the pilot beam brightness cannot be set Note If in a selected program at least one parameter is changed in the start menu and is confirmed with OK the text in...

Страница 65: ...displayed in the hand piece overview The selection bar is moved 6 lines up down using the keys PAGE UP PAGE DOWN The keys and can be used to move the highlighter bar up and down to find the required...

Страница 66: ...put field appears on the touchscreen Characters can be entered by pressing the number and letter keys and pressing the SPACE bar generates a space The arrow key moves the input cursor one character to...

Страница 67: ...mber of the newly definable programs is limited Once the maximum number of programs is reached the touchscreen shows the message ATTENTION Crea tion of another program not possible when an attempt is...

Страница 68: ...ference do not correspond with the values on the touchscreen take the following steps When the detector calibration key in the start menu is pressed the detector calib ration menu opens With the aid o...

Страница 69: ...the reference value is accepted and you are returned to the detector calibration menu The change is performed in the Change reference value menu with the aid of the arrow keys and Note The reference i...

Страница 70: ...ero value begins automatically Duration of the measurement is 2 seconds 4 17 4 Determining the reference value The following instruction appears on the touchscreen Hold instrument on reference sample...

Страница 71: ...ormation appears on the touchscreen The detector calibration was successfully completed Pressing the OK key saves the result and returns you to the start of the menu Pressing the Repeat detector calib...

Страница 72: ...ter flow See also Handpiece instructions Note Ensure that the laser tube is inserted into the input coupling and is screwed tight and that a handpiece is mounted Ensure that the KEY Laser 1243 is swit...

Страница 73: ...e KEY Lasers 1243 CAUTION Hazards from the unsupervised use of lasers Before leaving the treatment room turn off the KEY Laser 1243 and protect against unauthorized use Turn off the main power switch...

Страница 74: ...nd painted surfaces and plastics may be damaged Tests have shown that surfaces cannot be protected entirely against all substances available on the market As damage to surfaces is very much dependent...

Страница 75: ...a guideline we have provided you with a list of recommended concentrations of disinfectant ingredients as tested by us Note The levels shown are maximum levels and must not be exceeded 96 ethanol 40g...

Страница 76: ...e 5 3 Care sterilisability and disinfectability of handpieces 5 3 Care sterilisability and disinfectability of handpieces Information on the care sterilisation and disinfecting of KaVo handpieces can...

Страница 77: ...it contains a water cooler for cooling Never tip the KEY Laser 1243 or lay it on its side Note Please note that an ion exchanger is located inside the cooling circulation This deionizes the distilled...

Страница 78: ...hs at the latest KaVo recommends carrying out the annual maintenance service before the safety checks See also 2 Safety Page 11 Please read laser safety section carefully 6 1 Scope of the tests Comple...

Страница 79: ...safety check report page should be photocopied and completed in full You should then attach the form to the medical device record and customer service report See also 6 7 Safety check report Page 82 N...

Страница 80: ...uctions for use KEY Laser III 1243 6 Safety checks 6 3 Handpieces 6 3 Handpieces Check the transmission of the handpieces 2061 2062 and 2063 according to the instructions accompanying the handpieces 7...

Страница 81: ...dings taken are higher than this determine and remedy the cause The earthed conductor test and the spare unit leakage current test are performed after removal of the side casing on the right Perform t...

Страница 82: ...to DIN VDE 0751 1 Requirement Before the tester is started the key switch of the KEY laser should be kept in the on position until the test is complete The spare unit leakage current test should be ca...

Страница 83: ...g lamp Monitoring of cooling system Energy monitoring regulation Shutter absorber Safety foot control Check external safety systems Warning signs Check whether the required warning signs are mounted a...

Страница 84: ...J Software version KEY Commissioning date Operating period hours Last reset date for operating period counter Operating period hours Last safety check Energy readings f Hz E mJ Mean Minimum Maximum S...

Страница 85: ...ctions for use KEY Laser III 1243 7 Accessories 7 1 Handpieces 7 Accessories Note You must adhere to the above safety instructions See also 2 2 Laser safety Page 12 2 3 Safe use Page 14 7 1 Handpieces...

Страница 86: ...handpieces listed below have been tested and approved for use with the KEY Laser 1243 The accompanying contra angle handpiece 2060 Mat no 1 000 4841 The accompanying handpiece 2061 Mat no 1 000 6050...

Страница 87: ...2 Warning signs 7 2 Warning signs The KEY Laser 1243 is supplied with three sets of warning signs They are used for labelling the laser area Further warning signs can be ordered from KaVo Warning sign...

Страница 88: ...since December 2008 see next segment Mat no 0 228 2202 Protective laser goggles for the dentist and assistant Lambda One Mat no 1 006 4435 Protective laser goggles with mask design for the pati ent an...

Страница 89: ...erences 7 4 References Reference AMat no 1 000 9603 Reference BMat no 1 000 9604 Reference CMat no 1 000 8552 Reference DMat no 1 000 9605 Reference EMat no 1 000 9606 Reference FMat no 1 000 9607 Ref...

Страница 90: ...matic self tests which control the unit are installed in the unit Thus lamp ageing and deadjustment are automatically compensated for example via a microprocessor controlled energy regulation system w...

Страница 91: ...on the information appears on the touchscreen only on exiting the ready mode When the Continue key is pressed it is possible to continue working in the Ready mode Note The spray reservoir should howev...

Страница 92: ...age should be noted and the responsible service see Section A 1 5 After Sales Service should be informed In the event of fault message first check whether the trigger is operated or was operated on sw...

Страница 93: ...handpiece poor Spray nozzle furred or soiled Pierce spray nozzle with a jet needle A jet needle is included among the accessories See also Handpiece instructions Clean spray nozzle See also Handpiece...

Страница 94: ...e treatment room are provided with door swit ches and are opened Close the entrance doors No door switches are installed and the jumper for the door contact con nection is not correctly inserted Corre...

Страница 95: ...according to DIN 1055 Sheet 3 and must have a compressive strength according to DIN 18560 T1 The KEY Laser 1243 is delivered with soft castors from the factory Note The castors may not be used on sof...

Страница 96: ...The KEY Laser 1243 has an internal spray water supply The spray water reservoir bottle may be filled only with distilled or demineralized water neutral pH See also 4 2 Filling spray water Page 37 9 2...

Страница 97: ...t unit Mains cable unit connector and mains connector requirements 230V rated voltage 16 A rated current Length 3m Mains cable H05VV F3 1 50 3 x 1 5 mm not shielded Unit connector compliant with IEC 6...

Страница 98: ...inting upwards Handle with care Keep dry Note Once the KEY Laser has been taken out of its packaging the transit bracket on the compressor two cylinder head screws M 5x30 Mat no 0 249 4187 and two sle...

Страница 99: ...Goods and packaging must always be left unchanged and the goods must not be used Report the damage to the transport company Contact KaVo Shipping Department within 4 days Tel 0 73 51 56 0 Under no ci...

Страница 100: ...ions for use KEY Laser III 1243 9 Assembly notes 9 6 Installation plan 9 6 Installation plan The installation plan provides information about Space required treatment position See also Installation pl...

Страница 101: ...nit Page 27 An opener can be connected here This means that if an entrance door to the KEY Laser 1243 treatment room is opened the door switch too must be opened If there are several entrance doors al...

Страница 102: ......

Страница 103: ...1 001 1452 kb 20080813 07 en...

Отзывы: