GD32A50x User Manual
593
Figure 22-3. CMP hysteresis
CMP_OUT
CMP_IM-V
hyst
CMP_IM
CMP_IP
22.3.6.
CMP interrupt
The CMP output is connected to the EXTI and the EXTI line is exclusive to CMP. With this
function, CMP can generate either interrupt or event which could be used to exit from sleep
modes or deep-sleep modes.