Troubleshooting, Maintenance, and Care
Troubleshooting
8
8-9
Test Reports
Problem
Probable Cause
Action
Test Report shows multiple
unexpected failures on a single
phase (Voltage Phase B or
Current Phase C etc.)
Voltage and current
connections to the UUT do not
match the UUT Personality
Phase Order or a voltage
connection is open circuit.
1. Check the signal connections for the
failing phase matches the UUT
Personality Phase Order.
2. For multiple Voltage Phase failures,
check the corresponding connections
between the 6135A and the UUT by
applying a low voltage such as 10 volts
to single phases one at a time. Note:
consult the 6105A Users Manual to see
how to manually configure and operate
the 6135A from the 6105A front panel.
3. Check for a short circuit between the Hi
and Lo of the failing Current Phase.
Test failures on a Current Phase
cannot be caused by open circuit
current connections as the 6135A/PMU
Calibrator would report voltage over
compliance errors and the system
would stop. Failures on one Current
Phase do not indicate connections are
swapped with another phase or both
phases would fail.
Test Report shows multiple
unexpected failures on two
Voltage phase, two Current
phases or both.
Two Voltage phases, two
Current phases or both
connections do not match the
UUT Personality Phase Order.
1. Check the signal connections for the
failing phases match the UUT
Personality Phase Order.
2. See 2. and 3. in the previous row of this
table.
Test Report shows multiple
unexpected failures on all
Voltage phase or all Current
phases or both.
All three Voltage phases, all
three Current phases or all
voltage and current phase
connections do not match the
UUT Personality Phase Order.
1. Check the signal connections for the
failing phases match the UUT
Personality Phase Order.
2. See 2. and 3. in the first row of this
table.
Содержание 6135A/PMU
Страница 28: ...6135A PMU Operators Manual 2 2...
Страница 44: ...6135A PMU Operators Manual 3 2...
Страница 70: ...6135A PMU Operators Manual 3 28...
Страница 72: ...6135A PMU Operators Manual 4 2...
Страница 92: ...6135A PMU Operators Manual 4 22 gtu135 jpg Figure 4 12 Problem All Outputs Forced Off...
Страница 94: ...6135A PMU Operators Manual 5 2...
Страница 102: ...6135A PMU Operators Manual 5 10...
Страница 104: ...6135A PMU Operators Manual 6 2...
Страница 120: ...6135A PMU Operators Manual 7 2...
Страница 138: ...6135A PMU Operators Manual 7 20 gtu120 emf Figure 7 18 Example Report...
Страница 140: ...6135A PMU Operators Manual 8 2...
Страница 150: ...6135A PMU Operators Manual 9 2...
Страница 160: ...6135A PMU Operators Manual A 4...