background image

ABOUT THIS MANUAL

This booklet is an integral and essential part of the product and 

should be handed over to the operator after the installation and 

preserved for any further consultation that may be necessary. 

Please read carefully the guidelines and warnings contained 

herein as they are intended to provide the user with essential 

information for the continued safe use and maintenance of the 

product. In addition, it provides 

GUIDANCE ONLY

 to the user on 

the correct services and site location of the unit.

BEFORE GETTING STARTED

Each unit is tested under operating conditions and is thoroughly 

inspected before shipment. At the time of shipment, the carrier 

accepts responsibility for the unit. Upon receiving the unit,  

carefully inspect the carton for visible damage. If damage exists, 

have the carrier note the damage on the freight bill and file a 

claim with carrier. Responsibility for damage to the dispenser lies 

with the carrier.

IMPORTANT SAFETY INSTRUCTIONS

The installation and relocation, if necessary, of this product must be carried out by qualified personnel with 

 

up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.

LANCER PN: 28-3023/01
Revision: February 2019

®

2300

FOR QUALIFIED INSTALLER ONLY.

 This basic Installation Sheet is an initial release. If a complete 

Operations Manual (for the unit being installed) is required or needed, please refer to the Lancer web 

site (lancercorp.com) for immediate access, or for your convenience, scan this QR code with a mobile 

device (app required) for immediate access to other Technical Documents and alternative translations  

(if available) pertaining to this unit. Contact Lancer Customer Service for assistance as required.

The dispenser is for indoor use only. This unit is not a toy. Children should not be supervised not to play with appliance. It should 

not be used by children or infirm persons without supervision. This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given  

supervision or instruction concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance 

shall not be performed by children without supervision. The min/max ambient operating temperature for the dispenser is 40°F to 

90°F (4°C to 32°C). Do not operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of 

the unit and contact authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained  

personnel. Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.

Intended Use

Ice Cooled Drop-In Series 2300

Standard Performance

LANCER INSTALLATION GUIDE

Check the dispenser name plate label, located behind the splash plate, for the correct electrical requirements of unit.

 Do not plug 

into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available. Follow all local 

electrical codes when making connections. Each dispenser must have a separate electrical circuit. Do not use extension cords with 

this unit. Do not ‘gang’ together with other electrical devices on the same outlet. The key-switch does not disable the line voltage to 

the transformer primary. Always disconnect electrical power to the unit  to  prevent  personal injury before attempting any internal 

maintenance. The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source 

to service the unit. Only qualified personnel should service internal components of electrical control housing. Make sure that all 

water lines are tight and units are dry before making any electrical connections!

Electrical Warning

•  WARNING:

 Carbon Dioxide (CO2) is a colorless, noncombustible gas with a light pungent odor. High percentages of CO

2

 may 

displace oxygen in the blood. 

•  WARNING: 

Prolonged exposure to CO

2

 can be harmful. Personnel exposed to high concentrations of CO

2

 gas will experience 

tremors which are followed by a loss of consciousness and suffocation. 

•  WARNING: 

If a CO

2

 gas leak is suspected, immediately ventilate the contaminated area before attempting to repair the leak. 

•  WARNING: 

Strict attention must be observed in the prevention of CO

2

 gas leaks in the entire CO

2

 and soft drink system.

Carbon Dioxide (CO

2

)

Содержание 2300 Series

Страница 1: ...or instruction concerning use of the appliance by a person responsible for their safety Cleaning and user maintenance shall not be performed by children without supervision The min max ambient operati...

Страница 2: ...tion and operation of this dispenser If service is required please call your Lancer Service Agent or Lancer Customer Service Always have your model and serial number available when you call READ THIS...

Страница 3: ...Counter Location The installation and relocation if necessary must be carried out by qualified personnel with up to date knowledge and practical experience in accordance with current regulations NOTE...

Страница 4: ...using oetiker pliers and fittings see Plumbing Diagrams on the front of the unit or on pages 10 11 for reference 13 Route appropriate tubing from the syrup pump location through the shipping riser leg...

Страница 5: ...in 22 Install power supply assembly to bottom plate of free standing conversion kit or under counter 23 Route the power supply cord to a grounded electrical outlet of the proper voltage and amperage r...

Страница 6: ...r fatal electrical shock The power cord has a three prong grounded plug If a three hole grounded electrical outlet is not available use an approved method to ground the unit Follow all local electrica...

Страница 7: ...e there is ice on the cold plate and the lines are cold before attempting to set the flow rates on the valves The drink temperature should be no higher than 40 F 4 4 C when flow rates are set NOTE A B...

Страница 8: ...precautions DO NOT use a water jet to clean or sanitize the unit DO NOT disconnect water lines when cleaning and sanitizing syrup lines to avoid contamination DO NOT use strong bleaches or detergents...

Страница 9: ...h warm water and flush out syrup remaining in the lines 4 Prepare Cleaning Solution described on previous page Following sanitation rinse with end use product until there is no aftertaste Do not use a...

Страница 10: ...10 ILLUSTRATIONS DIAGRAMS 2300 6 Valve Standard Plumbing Diagram 2300 8 Valve Standard Plumbing Diagram 2300 10 Valve Standard Plumbing Diagram...

Страница 11: ...TIONAL Right Side Bin Switch Right Side Key Switch LEFT BANK OF VALVES RIGHT BANK OF VALVES CENTER BANK OF VALVES Right Side Power Supply Left On Top Right On Bottom Key Switch Orientation Wall Outlet...

Страница 12: ...CUTOUT 23 1 4 591 mm 25 5 648 mm 2300 Counter Cutout Diagram To prevent possible harm to the environment from improper disposal recycle the unit by locating an authorized recycler or contact the retai...

Отзывы: