UUT Calibration Setup
Connect the Calibration System to a UUT
4
4-7
Voltage Connections
Connect the voltage leads from the Calibration System Input/Output Panel to the UUT as
follows (refer to Figure 4-3):
Note:
The voltage leads supplied with the system provide 4 wire connection to the
front panel of the 6135A should that be required for other applications.
For PMU calibration 4 wire connection is not required but for safety all
connections should be made as described below.
1.
Connect the
Blue
voltage wire to the
Black Voltage Lo Output
.
2.
Connect the
Black
voltage wire into the back of the
Blue
wire connector.
3.
Connect the
Brown
voltage wire to the
Red Voltage LO Output
.
4.
Connect the
Red
voltage wire into the back of the
Blue
wire connector.
On the rear panel of the UUT for each phase in turn:
1.
Connect the
Red
voltage wire to the
Positive Voltage Inpu
t
.
2.
Connect the
Black
voltage wire to the
Negative Voltage Input, Ground
,
or
Common
.
Note
If the UUT does not have a negative voltage input or ground, you can
connect all of the black voltage wires together and put them in the common
input terminal on the UUT.
PMU UUT
Input/Output Panel
VOLTAGE INPUT
gtu140.emf
Figure 4-3. Voltage Connections (Three Sets of Voltage Shown)
Содержание 6135A/PMU
Страница 28: ...6135A PMU Operators Manual 2 2...
Страница 44: ...6135A PMU Operators Manual 3 2...
Страница 70: ...6135A PMU Operators Manual 3 28...
Страница 72: ...6135A PMU Operators Manual 4 2...
Страница 92: ...6135A PMU Operators Manual 4 22 gtu135 jpg Figure 4 12 Problem All Outputs Forced Off...
Страница 94: ...6135A PMU Operators Manual 5 2...
Страница 102: ...6135A PMU Operators Manual 5 10...
Страница 104: ...6135A PMU Operators Manual 6 2...
Страница 120: ...6135A PMU Operators Manual 7 2...
Страница 138: ...6135A PMU Operators Manual 7 20 gtu120 emf Figure 7 18 Example Report...
Страница 140: ...6135A PMU Operators Manual 8 2...
Страница 150: ...6135A PMU Operators Manual 9 2...
Страница 160: ...6135A PMU Operators Manual A 4...