Adjusting the Graph Display
Reference
3Ć72
H
No unit - When HPUI/LPUI is the Y axis component, the range is:
Linear Scale:-1000.0 T to 1000.0 T
Log Scale:0.01 p to 1000.0 T or -0.01 p to -1000.0 T
NOTE
T represents SI prefix symbol indicating 10
12
.
X Axis (Horizontal Axis)
The value at the right edge of the X axis, the value of 1 DIVISION (effective
only in case of linear scale) and the value at the left edge can be adjusted
with the [X RIGHT], [X DIVISION] and [X LEFT] selectors respectively (see
Figure 3Ć27). After one of these values is adjusted, the curves are reĆdisĆ
played. The relationship between these three values is as follows:
Linear Scale
X Division - The X axis is divided into 6 to 10 divisions. The value for 1
division is limited to either one of the following values.
±
0.01,
±
0.02,
±
0.05,
±
0.1,
±
0.2,
±
0.5,
±
1.0,
±
2.0,
±
5.0,
±
10.0,
±
20.0,
±
50.0
When the X division is changed, the X right is automatically adjusted.
X Right - When X right is changed, an optimum number of divisions and X
division are calculated from the X right and X left. The changed X right is
further adjusted automatically depending on other values.
X Left - When the X left is changed, the X right is automatically adjusted. So
when you change X left, the graph moves to the right or left in the data
space while keeping the size of the graph constant. When you change the X
right or X division, the horizontal size of the graph increases or decreases
while X left remains constant.
Log Scale
X Division - Cannot be changed by user.
X Right - The value taken by X right is a decade unit. If a value other than a
decade is entered, the input value will automatically be adjusted to the
nearest upper or lower decade value depending on the positive or negative
X right value.
When the parity of the X right is changed, the parity of the X left is also
changed.
X Left - The value taken by X left is a decade unit. If a value other than
decade is entered, the input value will automatically be adjusted to the
nearest lower or upper decade value depending on the positive or negative
X left value.
Summary of Contents for 372
Page 4: ......
Page 6: ...About this Manual ii ...
Page 14: ...Contents x ...
Page 22: ...Contents xviii ...
Page 30: ...Consignes de Sécurité Safety Summary xxvi ...
Page 31: ...Getting Started ...
Page 32: ......
Page 36: ...Overview Getting Started 1Ć4 ...
Page 90: ...Tutorial Ć About the Sample Disk Getting Started 1Ć58 ...
Page 91: ...Operating Basics ...
Page 92: ......
Page 108: ...Mounting the Device Under Test Operating Basics 2Ć16 ...
Page 110: ...Before and After Floating Measurement Operating Basics 2Ć18 ...
Page 111: ...Reference ...
Page 112: ......
Page 174: ...Pulse Mode Reference 3Ć62 ...
Page 176: ...Auxiliary Voltage Supply Reference 3Ć64 ...
Page 186: ...Adjusting the Graph Display Reference 3Ć74 ...
Page 190: ...Mathematical Operation Reference 3Ć78 ...
Page 210: ...Zoom Reference 3Ć98 ...
Page 217: ...Text Editing on the Graph 372 User Manual 3Ć105 Figure 3Ć46 ăClear Labels PopĆup Menu ...
Page 218: ...Text Editing on the Graph Reference 3Ć106 ...
Page 228: ...Hardcopy Reference 3Ć116 ...
Page 230: ...Initializing the 372 Reference 3Ć118 ...
Page 234: ...Time Stamp Reference 3Ć122 ...
Page 236: ...Adjusting CRT Brightness Reference 3Ć124 ...
Page 238: ...ID Information Reference 3Ć126 ...
Page 254: ...Floppy Disk System Reference 3Ć142 ...
Page 280: ...Sample Programs Reference 3Ć168 ...
Page 286: ...GPIB Reference 3Ć174 ...
Page 287: ...Appendices ...
Page 288: ......
Page 292: ...Appendix B Specifications Appendices AĆ4 ...
Page 312: ...Appendix B Specifications Appendices AĆ24 ...
Page 358: ...Appendix B Specifications Appendices AĆ70 ...