Measurement
Reference
3Ć66
Stop Measurement
ăStep 2:ă
Press the [STOP] button on the front panel to immediately stop
the measurement (see Figure 3Ć25).
When measurement is terminated, the SINGLE indicator goes out.
Repeated Measurement
Start Measurement
ăStep 1:ă
Press the [REPEAT] button on the front panel to start repeated
measurement (see Figure 3Ć25).
This feature repeats the measurement until the [STOP], [SINGLE] or
[REPEAT] button is pressed. When the measurement begins, the REĆ
PEAT indicator is lit.
Each time measurement is made, the contents of the storage memory is
cleared and new measurement data is written into memory. The new
measurement data is also displayed as a graph in the MEASURE menu
and in the miniature graph in the CONFIG menu.
If you open the protective cover of the test fixture, the interlock mechaĆ
nism interrupts the measurement and the OUTPUT indicator and REĆ
PEAT indicator go out.
Delayed Stop
ăStep 2:ă
Press the [REPEAT] or [SINGLE] button on the front panel to
stop the measurement after the sweep completes.
When measurement is terminated, the OUTPUT indicator and REPEAT
indicator go out.
Stop Measurement
ăStep 3:ă
Press the [STOP] button on the front panel to immediately stop
the measurement.
When measurement is terminated, the REPEAT indicator goes out.
Dynamic Changes of Settings
Pulse parameters, averaging mode, acquisition parameters and settings in
the source setup section can be changed during measurement. If you use
the SETUP application menu, it is not necessary to return to the CONFIG
menu to change the settings while the repeated measurement is being
made.
Summary of Contents for 372
Page 4: ......
Page 6: ...About this Manual ii ...
Page 14: ...Contents x ...
Page 22: ...Contents xviii ...
Page 30: ...Consignes de Sécurité Safety Summary xxvi ...
Page 31: ...Getting Started ...
Page 32: ......
Page 36: ...Overview Getting Started 1Ć4 ...
Page 90: ...Tutorial Ć About the Sample Disk Getting Started 1Ć58 ...
Page 91: ...Operating Basics ...
Page 92: ......
Page 108: ...Mounting the Device Under Test Operating Basics 2Ć16 ...
Page 110: ...Before and After Floating Measurement Operating Basics 2Ć18 ...
Page 111: ...Reference ...
Page 112: ......
Page 174: ...Pulse Mode Reference 3Ć62 ...
Page 176: ...Auxiliary Voltage Supply Reference 3Ć64 ...
Page 186: ...Adjusting the Graph Display Reference 3Ć74 ...
Page 190: ...Mathematical Operation Reference 3Ć78 ...
Page 210: ...Zoom Reference 3Ć98 ...
Page 217: ...Text Editing on the Graph 372 User Manual 3Ć105 Figure 3Ć46 ăClear Labels PopĆup Menu ...
Page 218: ...Text Editing on the Graph Reference 3Ć106 ...
Page 228: ...Hardcopy Reference 3Ć116 ...
Page 230: ...Initializing the 372 Reference 3Ć118 ...
Page 234: ...Time Stamp Reference 3Ć122 ...
Page 236: ...Adjusting CRT Brightness Reference 3Ć124 ...
Page 238: ...ID Information Reference 3Ć126 ...
Page 254: ...Floppy Disk System Reference 3Ć142 ...
Page 280: ...Sample Programs Reference 3Ć168 ...
Page 286: ...GPIB Reference 3Ć174 ...
Page 287: ...Appendices ...
Page 288: ......
Page 292: ...Appendix B Specifications Appendices AĆ4 ...
Page 312: ...Appendix B Specifications Appendices AĆ24 ...
Page 358: ...Appendix B Specifications Appendices AĆ70 ...