Parameter Analysis Using the Cursor
Reference
3Ć90
TableĂ3Ć33:ăXGONOGO Cursor Readout(Cont.)
Items
Descriptions
TOLERANCE =
Tolerance is expressed in two ways:
absolute length between the center point and endpoint,
and percentage of the length between the center point
and endpoint to the X axis component of the center
point.
GONOGO =
Result of XGONOGO test to check whether the curve
passes over the bar. Possible results are:
PASS - passed and
FAIL - did not pass
Note:The result of the gonogo testing is displayed after
a measurement has been completed.
Movement of the Cursor
The XGONOGO cursor is a line connecting the two endpoints and the center
point. Select and move the points one at a time from the Move popĆup menu
driven by the [MOVE] selector (see Table 3Ć34). The Y axis components of
these points change when you move the cursor.
The point to be moved is indicated with downward arrow mark.
TableĂ3Ć34:ăXGONOGO Cursor Move Selection
Choices
Descriptions
POS1
Selects endpoint 1 to be moved. When endpoint 1 is
moved, the center point also moves between the two
endpoints. The X axis component of endpoint 2 remains
unchanged.
CENTER
Selects center point to be moved. When the center
point is moved, the two endpoints also move, keeping
the length between the endpoints and center point
constant.
POS2
Selects endpoint 2 to be moved. When endpoint 2 is
moved, the center point also moves between two endĆ
points. The X axis component of endpoint 1 remains
unchanged.
Summary of Contents for 372
Page 4: ......
Page 6: ...About this Manual ii ...
Page 14: ...Contents x ...
Page 22: ...Contents xviii ...
Page 30: ...Consignes de Sécurité Safety Summary xxvi ...
Page 31: ...Getting Started ...
Page 32: ......
Page 36: ...Overview Getting Started 1Ć4 ...
Page 90: ...Tutorial Ć About the Sample Disk Getting Started 1Ć58 ...
Page 91: ...Operating Basics ...
Page 92: ......
Page 108: ...Mounting the Device Under Test Operating Basics 2Ć16 ...
Page 110: ...Before and After Floating Measurement Operating Basics 2Ć18 ...
Page 111: ...Reference ...
Page 112: ......
Page 174: ...Pulse Mode Reference 3Ć62 ...
Page 176: ...Auxiliary Voltage Supply Reference 3Ć64 ...
Page 186: ...Adjusting the Graph Display Reference 3Ć74 ...
Page 190: ...Mathematical Operation Reference 3Ć78 ...
Page 210: ...Zoom Reference 3Ć98 ...
Page 217: ...Text Editing on the Graph 372 User Manual 3Ć105 Figure 3Ć46 ăClear Labels PopĆup Menu ...
Page 218: ...Text Editing on the Graph Reference 3Ć106 ...
Page 228: ...Hardcopy Reference 3Ć116 ...
Page 230: ...Initializing the 372 Reference 3Ć118 ...
Page 234: ...Time Stamp Reference 3Ć122 ...
Page 236: ...Adjusting CRT Brightness Reference 3Ć124 ...
Page 238: ...ID Information Reference 3Ć126 ...
Page 254: ...Floppy Disk System Reference 3Ć142 ...
Page 280: ...Sample Programs Reference 3Ć168 ...
Page 286: ...GPIB Reference 3Ć174 ...
Page 287: ...Appendices ...
Page 288: ......
Page 292: ...Appendix B Specifications Appendices AĆ4 ...
Page 312: ...Appendix B Specifications Appendices AĆ24 ...
Page 358: ...Appendix B Specifications Appendices AĆ70 ...