Tutorial Ć Time Domain Measurement
Getting Started
1Ć52
H
Touch the [Y DATA] selector to display the YĆDATA popĆup menu.
H
Touch the [HPUI] box to select the drain current to be measured for
the Y axis.
H
Touch the [Y SCALE] selector to display the YĆSCALE popĆup menu.
H
Touch the [LIN] box to set the Y axis to linear scale.
ăStep 5:ă
Set the scroll mode for the X axis as follows:
H
Touch the [SCROLL MODE] selector to display the Scroll Mode
popĆup menu.
H
Select the [NO SCROLL] box to set the X axis to No Scroll mode.
The above are the default settings. If the parameters have not been
switched to another setting, these steps can be omitted.
Source Setup
Actual operation values of each SMU must be set. The start and stop value
of the HPU and LPU are the value at which the measurement starts and the
value set in the hold time after measurement starts (see Figure 1Ć48).
ăStep 6:ă
With the selectors in the Source Setup section, set the source
parameters.
The relationships between various source setup values and selectors
are shown in Table 1Ć4.
TableĂ1Ć4:ăExample of Time Domain Measurement Setup
Source Units Selectors
PopĆup Menu
Settings
START
Numeric
0.00 mV
STOP
Numeric
-500.00 mV
LPU
MEASURE RANGE
Box
1.0
m
A
COMPLIANCE
Numeric
10.0
m
A
RESISTANCE
Box
0 k
W
START
Numeric
20.0 V
STOP
Numeric
20.0 V
HPU
MEASURE RANGE
Box
100 mA
COMPLIANCE
Numeric
30.0 mA
RESISTANCE
Box
0 k
W
Summary of Contents for 372
Page 4: ......
Page 6: ...About this Manual ii ...
Page 14: ...Contents x ...
Page 22: ...Contents xviii ...
Page 30: ...Consignes de Sécurité Safety Summary xxvi ...
Page 31: ...Getting Started ...
Page 32: ......
Page 36: ...Overview Getting Started 1Ć4 ...
Page 90: ...Tutorial Ć About the Sample Disk Getting Started 1Ć58 ...
Page 91: ...Operating Basics ...
Page 92: ......
Page 108: ...Mounting the Device Under Test Operating Basics 2Ć16 ...
Page 110: ...Before and After Floating Measurement Operating Basics 2Ć18 ...
Page 111: ...Reference ...
Page 112: ......
Page 174: ...Pulse Mode Reference 3Ć62 ...
Page 176: ...Auxiliary Voltage Supply Reference 3Ć64 ...
Page 186: ...Adjusting the Graph Display Reference 3Ć74 ...
Page 190: ...Mathematical Operation Reference 3Ć78 ...
Page 210: ...Zoom Reference 3Ć98 ...
Page 217: ...Text Editing on the Graph 372 User Manual 3Ć105 Figure 3Ć46 ăClear Labels PopĆup Menu ...
Page 218: ...Text Editing on the Graph Reference 3Ć106 ...
Page 228: ...Hardcopy Reference 3Ć116 ...
Page 230: ...Initializing the 372 Reference 3Ć118 ...
Page 234: ...Time Stamp Reference 3Ć122 ...
Page 236: ...Adjusting CRT Brightness Reference 3Ć124 ...
Page 238: ...ID Information Reference 3Ć126 ...
Page 254: ...Floppy Disk System Reference 3Ć142 ...
Page 280: ...Sample Programs Reference 3Ć168 ...
Page 286: ...GPIB Reference 3Ć174 ...
Page 287: ...Appendices ...
Page 288: ......
Page 292: ...Appendix B Specifications Appendices AĆ4 ...
Page 312: ...Appendix B Specifications Appendices AĆ24 ...
Page 358: ...Appendix B Specifications Appendices AĆ70 ...