TM 11-6625-3145-14
Verification and Adjustment Procedures-318/338 Service
7.
Set the serial data generator power to ON, and select DTE SIMULATE mode.
8.
Set serial data generator SETUP as follows;
CODE=ASCII, BAUD=2400, DUPLEX-FULL, SETUP=ASYNC, BITS/CHAR=8,
PARITY= NONE, STOPBITS = 1, TIMING = NORMAL.
9.
Load the following program into the serial data generator:
STEP
MNEMONIC
CODE
1
SEND
#1
2
JMP
#1
10.
Load the following hexadecimal data in the serial data generaotor buffuffer #1: E0, E0, E2, E4, E6, E8
11.
Press the START key on the serial data generator.
12.
Select the DATA DISPLAY STATE TABLE and press the START key.
13.
When the 338 displays data on the crt, press the serial data generator STOP key.
14.
Check that the 338 display matches the WORD SEQUENCE column on Table 5-25.
15.
Set the 338 baud rate to 19.2K (DATA screen).
16.
Set the serial data generator baud rate to 19.2K.
17.
Set the 338 and the serial data generator controls as indicated in step 1 of Table 5-25 and repeat preceding parts
(11) through (14).
Repeat steps 2 through 7 for the remainder of Table 5-25.
NOTE
Selection field for BITS/’WORD and COM.MODE (SYNC or ASYNC) and BAUD RATE
appear in the 338 SETUP Menu. Selection fields for SYNC WORD and HUNT WORD
are in the TRIGGER Menu.
To load SETUP parameters into the serial data generator, the operator must: (a) press SETUP, (b) select SETUP item
using LEFT or RIGHT Vector keys. (c) select SETUP parameters using UP or DOWN VECTOR key.
To load data into the serial data generator buffer #1, the operator must: (a) press PROGRAM, (b) press RIGHT VECTOR,
(c) press DOWN VECTOR, (d) press keys for the two hexadecimal characters to be entered, and (e) press ENTER. To
load additional data , repeat parts (d) and (e).
To load the program into the serial data generator, the operator must: (a) press PROGRAM, (b) select program code by
LEFT or RIGHT VECTOR, (c) if program code includes distination number, press alphanumeric key to be entered, and
press ENTER, (d) press DOWN VECTOR, to next program step.
5-118
Summary of Contents for 318
Page 119: ...318 VERIFICATION AND ADJUSTMENT PROCEDURES ...
Page 182: ...338 VERIFICATION AND ADJUSTMENT PROCEDURES ...
Page 253: ...318 ___________________ TROUBLESHOOTING TREES ...
Page 344: ...338 TROUBLESHOOTING TREES ...
Page 517: ...TM 11 6625 3145 14 318 338 4434 923 318 Block Diagram ...
Page 518: ...TM 11 6625 3145 14 318 338 4434 924 338 Block Diagram ...
Page 519: ...TM 11 6625 3145 14 318 338 4434 925 318 Acquisition Module Wiring Diagram ...
Page 520: ...TM 11 6625 3145 14 318 338 4434 926 318 338 Mainframe Wiring Diagram ...
Page 521: ...TM 11 6625 3145 14 318 338 4434 926 338 Acquisition Module Wiring Diagram ...
Page 522: ...TM 11 6625 3145 14 318 338 4434 928 Figure 9 1 318 A01 Input A Board Component Locations ...
Page 526: ...TM 11 6625 3145 14 ...
Page 528: ...TM 11 6625 3145 14 Figure 9 3 318 338 A03 ACQ Control Board Component Locations ...
Page 532: ...TM 11 6625 3145 14 ...
Page 536: ...TM 11 6625 3145 14 ...
Page 538: ...TM 11 6625 3145 14 ...
Page 539: ...TM 11 6625 3145 14 ...
Page 540: ...TM 11 6625 3145 14 ...
Page 541: ...TM 11 6625 3145 14 ...
Page 542: ...TM 11 6625 3145 14 Figure 9 8 318 338 A10 CRT Board Component Locations ...
Page 544: ...TM 11 6625 3145 14 Figure 9 9 318 338 A11 Inverter Board component Locations ...
Page 546: ...TM 11 6625 3145 14 Figure 9 10 318 338 A12 Regulator Board Component Locations ...
Page 551: ...TM 11 6625 3145 14 Figure 9 12 338 A01 Input A Board Component Locations ...
Page 553: ...TM 11 6625 3145 14 318 338 SERVICE ...
Page 554: ......
Page 555: ...PIN 058584 ...