1=Ready for operation
(DC link loaded, pulses disabled)
0=Not ready for operation
Function diagram
8
7
6
5
4
3
2
1
fp_mc_200_e.vsd
Status word 1
MASTERDRIVES MC
10.02.03
- 200 -
V2.5
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
Bit 15
1=Ready to switch on
0=Not ready to switch on
Meaning
1=Run
(voltage at output terminals)
0=Pulses disabled
1=Fault active (pulses disabled)
0=No fault
0=OFF2 active
1=No OFF2
0=OFF3 active
1=No OFF3
1=Switch-on inhibit
0=No switch-on inhibit (possible to switch on)
1=Warning active
0=No warning
1=No setpoint/actual value deviation detected
0=Setpoint/actual value deviation
1=PcD control requested
(always 1; Exception: clock-
synchronized operation acc. to PROFIdrive V3)
1=Comparison value reached
0=Comparison value not reached
1=Message low voltage
0=Message no low voltage
1=Request to energize main contactor
0=Request not to energize main contactor
1=Ramp-function generator active
0=Ramp-function generator not active
Reserve
1=Positive speed setpoint
0=Negative speed setpoint
Bit No.
Bit 0
from sequence control 1)
from sequence control 1)
from sequence control 1)
from sequence control 1)
from sequence control 1)
from sequence control 1)
from sequence control 1)
from sequence control 1)
from sequence control 1)
from alarm processing
from messages [480.5]
from messages [480.5]
from fault processing
from setpoint processing
(part 2) [320.5]
from messages [480.3]
1
1
1
1
1
1
1
1
1
1
1
1
1
1
The sequence control system is the
internal control system (software) for
implementing the drive status (r001).
1)
15
14
7
6
13
12
5
4
11
10
3
2
9
8
1
0
Display of r552 on the PMU
Status Word 1
r552
K0032
Status Word 1
B0100
Rdy for ON
B0101
Not Rdy for ON
B0102
Rdy for Oper
B0103
Not Rdy for Oper
B0104
Operation
B0105
Not operating
B0106
Fault
B0107
No fault
B0108
No OFF2
B0109
OFF2
B0110
No OFF3
B0111
OFF3
B0112
Blocked
B0113
Not Blocked
B0114
Warning
B0115
No Warning
B0116
No Deviation
B0117
Deviation
B0120
CompV OK
B0121
CompV not OK
B0122
Low Voltage
B0123
No Low Voltage
B0124
Energize MCon
B0125
N.Energ.MCon
B0126
RampGen active
B0127
RampGen n.act.
B0128
Speed Setp FWD
B0129
Speed Setp REV
n959.27 = 4