Unit rating [kW]
Standard
Unit rating [kW]
wit
h
F02
as ad
d
.
opti
o
n
Rated outpu
t cur
rent
IUn [A]
Short-time/overlo
ad current
Imax. [A]
Rated DC link
current
IZKn [A]
Line current
(onl
y
for c
onv
ert
e
rs
) [A]
Orde
r No.
Converter
Orde
r No.
Inverter
T
o
tal power
loss
Converter [kW]
T
o
tal power
loss
Inverter [kW]
Weight kg
Basic unit with F02 as additional
option
75
90
186
254
221
205
6SE7031–8EF70
6SE7031–8TF70
2.17
1.7 75
90
110
210
287
250
231
6SE7032–1EG70
6SE7032–1TG70
2.68 2.18 160
110
132
260
355
309
286
6SE7032–6EG70
6SE7032–6TG70
3.40 2.75 160
132
160
315
430
375
346
6SE7033–2EG70
6SE7033–2TG70
4.30 3.47 180
160
200
370
503
440
407
6SE7033–7EG70
6SE7033–7TG70
5.05 4.05 180
200
250
510
694
607
–
–
6SE7035–1TJ70
–
5.8 350
200
250
510
694
607
561
6SE7035–1EK70
–
7.10
– 400
250
315
590
802
702
–
–
6SE7036–0TJ70
–
6.6 350
250
315
590
802
702
649
6SE7036–0EK70
–
8.20
– 400
*400
690
938
821
–
–
6SE7037–0TJ70
–
8,8 350
*400
690
938
821
759
6SE7037–0EK70
–
10.20
– 400
*500
860 1170
1023
–
–
6SE7038–6TK70
– 11.9 520
*630
1100 1496
1310
–
–
6SE7041–1TK70
– 13.4 520
*710
1300 1768
1547
–
–
6SE7041–3TL70
– 14.5 625
* Performance extension: Only operable with P357 = 1 (max. 2.7 kHz)
(F02 as add. option is included)
Table 11-2
Overview of units which can be operated with F02 as an additional option