09.2008
Functions
Siemens AG
6SE7087-6QX70 (Version AK)
SIMOVERT MASTERDRIVES
Compendium Motion Control
7-21
Input (control signals)
Output
Homing on the fly
REF_TYP = 0
ENABLE
REF_ON
POS_ON
SETUP_ON
REF_
TYP
REF_STOP
REF_D
D_FWD
D_BWD
POS_TYP
ENABLE_POS_REF
B0870 1 x x x x x x x x x 1
REF
B0871 1 1 x x 0 x 1 x x x 1
POS
B0872 1 x 1 x 0 x x x x x 1
SETUP
B0873 1 x 0 1 0 x x 0 1 x 1
D_FWD_ACT
B0875 1 x 0 1 0 x 1 1 0 x 1
D_BWD_ACT
B0876 1 x 1 0 0 x 0 0 1 x 1
PSR
B0877 1 1 1 1 x x x x x x 1
REF_DRIVE
B0893 1 x x x 0 x x x x x 0
POS_TYP_ACT
B0874 1 0 1 x 0 x x x x 0 0
1 0 1 x 0 x x x x 1 1(V=0)
SET_REF_D
B0895 x x x x x x 1 x x x 1
Homing
REF_TYP = 1
ENABLE_POS_REF
B0870 1 x x x x x x x x x 1
REF
B0871 1 1 x x 1 0 1 x x x 1
POS
B0872 1 1 x x 1 x x x x x 0
SETUP
B0873 1 1 x x 1 0 x 0 1 x 1
D_FWD_ACT
B0875 1 1 x x 1 0 1 1 0 x 1
D_BWD_ACT
B0876 1 1 x x 1 0 0 0 1 x 1
PSR
B0877 1 1 x x x 0 x x x x 1
REF_DRIVE
B0893 1 1 x x 1 0 x (1)
*)
(1)
*)
x 1
POS_TYP_ACT
B0874 1 0 1 x 1 x x x x 0 0
1 0 1 x 1 x x x x 1 1(V=0)
SET_REF_D
B0895 x x x x x x 1 x x x 1
x= don't care
*)
Depending on selection of direction
D_FWD_ACT / D_BWD_ACT
Table 7-2
Mode truth table