Parameter
Description
Data
Read/write
P648*
Conf DigIn5
648
Function parameter for configuring digital input 5.
0 = Use as a normal digital input
1 = OFF2 with rising edge
2 = OFF2 with falling edge
3 = Adopt measured value of the position with rising edge
4 = Adopt measured value of the position with falling edge
5 = Adopt measured value depending on binector
index1: 0
Min: 0
Max: 5
Unit: -
Indices: 2
,BDS
Type: O2
Menus:
- Parameter menu
+ Terminals
- Upread/free access
Changeable in:
- Ready to switch on
P649*
S.Conf DigIn5
649
If parameter value 5 is set in parameter P647/648, then
this binector is used to change the transfer of the position
measurement between rising and falling edge.
Index 1: enable/disable position measurement recording
Index 2: selection of edge
If the binector has the value 0, the position measurement
is taken on a rising edge.
If the binector has the value 1, the position measurement
is taken on a falling edge.
index1: 1
Unit: -
Indices: 2
Type: L2 ,B
Menus:
- Parameter menu
+ Terminals
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P651*
S.DigOut1
651
BICO parameter for selecting the binector whose value is
to be output at terminal -X101/3 of the terminal strip for
the basic unit. In order to use terminal -X101/3 as a digital
input, both indices must be set to 0.
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,B
Menus:
- Parameter menu
+ Terminals
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P652*
S.DigOut2
652
BICO parameter for selecting the binector whose value is
to be output at terminal -X101/4 of the terminal strip for
the basic unit. In order to use terminal -X101/4 as a digital
input, both indices must be set to 0.
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,B
Menus:
- Parameter menu
+ Terminals
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P653*
S.DigOut3
653
BICO parameter for selecting the binector whose value is
to be output at terminal -X101/5 of the terminal strip for
the basic unit. In order to use terminal -X101/5 as a digital
input, both indices must be set to 0.
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,B
Menus:
- Parameter menu
+ Terminals
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P654*
S.DigOut4
654
BICO parameter for selecting the binector whose value is
to be output at terminal -X101/6 of the terminal strip for
the basic unit. In order to use terminal -X101/6 as a digital
input, both indices must be set to 0.
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,B
Menus:
- Parameter menu
+ Terminals
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P655*
EB1 Signal Type
655
Parameter for selection of the signal type for analog input
1 on EB1.
0 = +/- 10 V
1 = +/- 20 mA
Index 1: AI1 of the first inserted EB1
Index 4: AI1 of the second inserted EB1
Index 2, 3, 5 and 6: no significance
index1: 0
Min: 0
Max: 1
Unit: -
Indices: 6
Type: O2
Menus:
- Parameter menu
+ Terminals
- Upread/free access
Changeable in:
- Ready to switch on
P656*
EB1 AnaInNorm
656
Parameter for normalization of the analog inputs on EB1.
Incoming signals are multiplied by the entered parameter
value.
Index 1 to 3: AI1 to AI3 of the first inserted EB1
Index 4 to 6: AI1 to AI3 of the second inserted EB1
index1: 1,00
Min: 0,00
Max: 100,00
Unit: -
Indices: 6
Type: O2
Menus:
- Parameter menu
+ Terminals
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
80
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control