08.2012
Technology Option F01
Siemens AG
6SE7087-6QX70 (Version AN)
SIMOVERT MASTERDRIVES
Compendium Motion Control
9-39
Encoder: Resolver
(P171=12
≅
4096
increments/revolution)
Gear ratio:
1:10
Diameter of drive roller:
300 mm
How many µm does the slide travel in one encoder increment?
AVWF = number of LUs per position increment
revolution
inc /
1
Diameter
ratio
Gear
1
=
inc
m
AVWF
×
π
×
×
μ
[ ]
[ ]
inc
2
1
m
D
i
1
=
inc
m
AVWF
P171
×
μ
×
π
×
μ
inc
4096
1
m
300000
10
1
=
inc
m
AVWF
×
π
×
μ
×
μ
m
1828
23,0097118
=
inc
m
AVWF
μ
μ
Resulting Actual Value Weighting Factor (AVWF)
Integer places
3-digit P169
Decimal places
8-digit P170
23 (00)971181
Trailing zeroes must be entered with the decimal place component;
leading zeroes can be omitted.
Examples:
AVWF = 12.3
→
P169 = 12, P170 = 30000000
AVWF = 12.00000003
→
P169 = 12, P170 = 3
When the actual value weighting factor (AVWF) is specified as a
numerator / denominator, the length units LU are entered in the
numerator and the encoder increments in the denominator.
Example:
A rotary axis is driven via a gear unit with a gear ratio of 1:3. The actual
position sensing function is parameterized such that 2
16
increments
correspond to one motor revolution. One revolution on the load side
must equal 360000LU.
196608
360000
3
2
360000
AVWF
16
=
⋅
=
NOTE
AVWF as numerator/
denominator