Parameter
Description
Data
Read/write
U462*
Sync Window
2462
Index 1
Internal window [F1]
Index 2
External window [F2]
F1 < synchronizing difference < F2:
If the synchronizing difference lies within the external
window, synchronizing is effected in the shortest way.
Synchronizing difference > F2:
If the synchronizing difference lies outside the outer
window, synchronizing is effected according to the
selected mode in a certain direction.
Synchronizing difference < F1:
If the synchronizing difference lies within the inner
window, no synchronizing movement takes place,
synchronous message is effected immediately (B0811)
and the established synchronizing difference is calculated
with the displacement. At window size 0, the internal
window is deselected (only external window still active).
index1: 0
Min: 0
Max:
2147483647
Unit: -
Indices: 2
Type: O4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U463*
S.Gl.RLEnable
2463
Index 1:
Binector source for release speed positive
Index 2:
Binector source for release speed negative
index1: 1
Unit: -
Indices: 2
Type: L2 ,B
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U464*
S.Gl.EnableSet
2464
Index 1:
Binector source for release displacement angle setting
Index 2:
Binector source for adding remaining distance to current
displacement
index1: 1
Unit: -
Indices: 2
Type: L2 ,B
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
n465
DispSpeed
2465
Index 1:
Current adjustment speed in percent referred to U697.2
[in function diagram 841]
Index 2:
Current adjustment speed including v_inching in percent
referred to U607 [in function diagram 841]
Dec.Plc.: 3
Unit: %
Indices: 2
Type: I4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
n466
Displ_Act_Resid
2466
Visualization parameter for offset angle setting
[in function diagram 841]
Index 1: Remaining offset path (KK827)
Index 2: Current offset (KK812)
Dec.Plc.: 0
Unit: -
Indices: 2
Type: O4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
U467*
PosCorrection
2467
Parameter for position correction
Function diagram [843.5]
Index 1: Correction speed [1000LU/min]
Index 2: Acceleration [1000LU/sec^2]
index1: 0,00
Min: 0,00
Max:
20000000,00
Unit: -
Indices: 2
Type: O4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U468*
PosCorrVFactor
2468
Speed adjustment in percent for U467.1
Init: 1
Unit: -
Indices: -
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
175
Siemens AG 6SE7087-6QX70 (Edition AL)