Technology Option F01
08.2012
6SE7087-6QX70 (Version AN) Siemens AG
9-152
Compendium Motion Control
SIMOVERT MASTERDRIVES
Binectors that are to be traced must first be entered in a connector
using a binector/connector converter [720].
♦
Recording signals with an oscilloscope or continuous-line
recorder:
The analog outputs on the converter terminal strip [80] and terminal
expansion boards EB1 and EB2 [Y01...Y08] are available for this
purpose.
♦
Checking high-speed switching operations on the PMU:
Thanks to its extremely high refresh time, the 7-segment PMU
parameter monitoring unit is ideal for checking high-speed switching
operations. You can monitor short-term level changes in all
positioning control and status signals on the PMU in n541.01... .04.
This is not possible on the OP1S or in DriveMonitor because of the
serial transfer times.
9.8.2
Commissioning the technology
Commissioning step:
Use an application example to get started with the technology:
If you are not yet familiar with the positioning and synchronization
functions in MASTERDRIVES MC, you should study the example
nearest to your application in the "Application examples" section using
one or two MASTERDRIVES MC units and one or two idling motors
(you only need 2 drives for synchronization). In application example 2,
for example, you are shown how to operate 2 MASTERDRIVES MC
converters in position control and synchronization mode. The complete
actuation system is implemented via the converter terminal strip (using
switches and a potentiometer). The application example also guides
you through the available documentation and the relevant function
diagrams.
The section below provides you with a general commissioning guide
which takes you step-by-step through the commissioning procedure. It
is impossible, of course, to cater for all special applications in this
guide.
NOTE