Parameter
Description
Data
Read/write
P612*
S.SigBrakeOp
612
BICO parameter for selecting the binector from which the
check-back message "Brake opened" is to be read in.
Init: 1
Unit: -
Indices: -
Type: L2 ,B
Menus:
- Parameter menu
+ Sequence control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P613*
S.SigBrakeClos
613
BICO parameter for selecting the binector from which the
check-back message "Brake closed" is to be read in.
Init: 0
Unit: -
Indices: -
Type: L2 ,B
Menus:
- Parameter menu
+ Sequence control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P614*
S.PBrakeClos
614
BICO parameter for selecting the binector from which the
command for closing a holding brake is to be read in.
Init: 0
Unit: -
Indices: -
Type: L2 ,B
Menus:
- Parameter menu
+ Sequence control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P615*
S.BrakeThresh2
615
BICO parameter for selecting the connector from which
the actual value for comparison with brake threshold 2 is
to be read in. Preferably, the actual speed (KK0091) is
selected as the actual value.
Init: 91
Unit: -
Indices: -
Type: L2 ,K
Menus:
- Parameter menu
+ Sequence control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P616
BrakeThresh2
616
Function parameter for entering brake threshold 2. If the
actual value falls below this threshold after an OFF
command, the brake is closed and a firing-pulse block is
initiated by the brake control unit (B278). The value
entered here should not be smaller than the turn-off value
parameterized in P800.
Init: 0,5
Min: 0,0
Max: 200,0
Unit: %
Indices: -
Type: O2
Menus:
- Parameter menu
+ Sequence control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P617
BrakeThresh2Time
617
Function parameter for entering the time by which closing
of the brakes is to be delayed after an OFF command. If
the threshold value falls below brake threshold 2 after an
OFF command, closing of the brake is delayed by the
time entered.
Init: 0,00
Min: 0,00
Max: 100,00
Unit: s
Indices: -
Type: O2
Menus:
- Parameter menu
+ Sequence control
+ Diagnostics
+ Messages/displays
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P618*
SrcFanControl
618
Compact PLUS only
Only for converter (AC-AC-unit) BICO parameter for
selecting the binector from which command for fan control
is given.
0=automatic fan control
1=Fan on permanently.
Init: 0
Unit: -
Indices: -
Type: L2 ,B
Menus:
- Parameter menu
- Upread/free access
Changeable in:
- Ready to switch on
P630*
AnaIn Scale
630
Function parameter for scaling the analog input on the
terminal strip of the basic unit. Incoming signals are
multiplied by the parameter value entered.
Init: 1,00
Min: 0,00
Max: 100,00
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Terminals
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
77
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control