Technology Option F01
08.2012
6SE7087-6QX70 (Version AN) Siemens AG
9-108
Compendium Motion Control
SIMOVERT MASTERDRIVES
MSG Basic Positioner
WRITE 2885 00 0x20
;
Input6
Synchronism local function ON
WRITE 2886 01 0x871
;Link betw. synchronism and position
setpoint
WRITE 2886 02 0x870
;Link betw. synchronism and speed
setpoint
WRITE 2953 61 4
; Enable basic positioner FB361 -789b-
in T4
WRITE 2856 00 1048576.00 ; BPOS rated speed
WRITE 2857 00 787.5
; BPOS rated acceleration
WRITE 2858 01 524288
; BPOS axis cycle
WRITE 2850 01 0x418
; BPOS position setpoint (constant
value B2018)
WRITE 2850 02 0x310
; BPOS feedback position setpoint
WRITE 2850 03 0x0
; BPOS position setting value
WRITE 2850 04 0x120
; BPOS Actual position for POS_Ok
checkback
WRITE 2850 05 0x310
; BPOS RM_IN FP789b
WRITE 2851 00 0x41
; BPOS positioning speed [%] P401
WRITE 2852 01 0x1
; BPOS adaptation speed UP
WRITE 2852 02 0x1
; BPOS adaptation speed DOWN
WRITE 2853 1 0x0
; BPOS preselect traversing direction
forwards
WRITE 2853 2 0x0
; BPOS preselect traversing direction
backwards
WRITE 2853 3 0x0
; BPOS setup mode
WRITE 2854 1 0x10
;
Input1
BPOS positioning<Start
TCW B5
WRITE 2854 2 0x16
;
Input4
BPOS positioning
Absolute(0)/Relative(1)
WRITE 2855 1 0x0
; BPOS set output
WRITE 2855 2 0x20
;
Input6
BPOS enable basic
positioner
WRITE 2656 1 0x3203
; Switchover to catch-up SYNC input
WRITE 2656 2 0x3203
...