Parameter
Description
Data
Read/write
P270*
S.I(sq,set)
270
BICO parameter for selecting the connector from which
the setpoint of the torque-forming current component is to
be read in.
index1: 166
Unit: -
Indices: 2
,BDS
Type: L2 ,K
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P271*
S.I(sq,add)
271
BICO parameter for selecting the connector from which
the additional setpoint for the torque-forming current
component is to be read in.The additional setpoint is
added to the setpoint.
index1: 0
Unit: -
Indices: 2
,BDS
Type: L2 ,K
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
r272
Isq (set,active)
272
Visualization parameter for displaying the setpoint of the
torque-forming current component Isq.
Dec.Plc.: 1
Unit: A
Indices: -
Type: I2
Menus:
- Parameter menu
+ Control/gating unit
+ Current control
- Upread/free access
P275*
S.I(max)
275
BICO parameter for selecting the connector from which an
external setpoint for the maximum current is to be read in.
index1: 2
Unit: -
Indices: 2
,BDS
Type: L2 ,K
Menus:
- Parameter menu
+ Control/gating unit
+ Speed control
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P282
Amps Reg Gain
282
Gain of the current controller.
In function diagram: 389.6, 390.6
Init: 80,0
Min: 0,0
Max: 200,0
Unit: %
Indices: -
Type: O2
Menus:
- Parameter menu
+ Control/gating unit
+ Current control
- Upread/free access
Changeable in:
- Ready to switch on
P285
Ki CurrReg
285
Integral component of the current controller
Only for special cases.
In function diagram: 389.7, 390.7
Init: 0,0
Min: 0,0
Max: 100,0
Unit: %
Indices: -
Type: O2
Menus:
- Parameter menu
+ Control/gating unit
+ Current control
- Upread/free access
Changeable in:
- Ready to switch on
r286
PosTestAngle
286
Visualization parameter for the position test.
The angle is represented in mechanical angular degrees
to two decimal places.
Wrong orientation of the motor encoder can be detected
when the rotor is aligned with impressed current in
position test mode.
Correction is made by rotating the encoder or by an entry
in P132.
In function diagram: 389.8, 390.8
Dec.Plc.: 2
Unit: -
Indices: -
Type: I4
Menus:
- Parameter menu
- Upread/free access
45
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control