![Siemens simovert masterdrives Compendium Download Page 1260](http://html.mh-extra.com/html/siemens/simovert-masterdrives/simovert-masterdrives_compendium_3781711260.webp)
Parameter
Description
Data
Read/write
P754*
Max SyncTimeSlot
754
Maximum time slot which is to be synchronized.
0: Synchronized time slot coresponds to bus cycle time.
Init: 0
Min: 0
Max: 10
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ SIMOLINK
- Upread/free access
Changeable in:
- Ready to switch on
P755*
SIMOLINK Conf
755
Function parameter for configuring various properties of
SIMOLINK transfer.
xxx0 No deadtime compensation
xxx1: Compensation of the different deadtimes between
transceiver-transceiver and transceiver-dispatcher-
transceiver.
xx0x: Switchover between 2 SLBs in operation disabled
xx1x: Switchover between 2 SLBs in operation enabled
x0xx: Bus cycle time is internally corrected to whole
telegram number
x1xx: Bus cycle time is implemented precisely
Init: 0
Unit: -
Indices: -
Type: L2
Menus:
- Parameter menu
+ SIMOLINK
- Upread/free access
Changeable in:
- Board configuration
- Ready to switch on
P756*
SrSLB_Specialdat
756
BICO parameter for selecting the parameters that are to
be sent from a SIMOLINK board (SLB) as special data.
Special data can be sent from an SLB master or
dispatcher only.
Index 1: Special telegram 1, low-word
Index 2: Special telegram 1, high-word
Index 3: Special telegram 2, low-word
...
Index 7: Special telegram 4, low-word
Index 8: Special telegram 4, high-word
In the case of double word connectors the relevant
connector number must be entered at 2 successive
indices as otherwise only the higher-value word will be
transmitted.
index1: 0
Unit: -
Indices: 8
Type: L2 ,K
Menus:
- Parameter menu
+ SIMOLINK
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P765*
SrcExtrapolPos
765
Input extrapolator/interpolator:
Index 1: Position setpoint block 1 [LU]
Index 2: Position setpoint block 2 [LU]
Index 3: Position setpoint block 3 [LU]
In function diagram 794b
index1: 0
Unit: -
Indices: 3
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P766*
SrcExtrapolSpeed
766
Input extrapolator/interpolator:
Index 1: Speed setpoint block 1 [%]
Index 2: Speed setpoint block 2 [%]
Index 3: Speed setpoint block 3 [%]
In function diagram 794b
index1: 0
Unit: -
Indices: 3
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
P767*
ExtrapolTimeSlot
767
Input parameter extrapolator/interpolator:
Indicates the time slot in which the position and speed
input values are generated.
Index 1: Slow time slot block 1
Index 2: Slow time slot block 2
Index 3: Slow time slot block 3
In function diagram 794b
index1: 2
Min: 2
Max: 10
Unit: -
Indices: 3
Type: O2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
100
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control