Parameter
Description
Data
Read/write
P060*
Menu Select
60
Function parameter for selecting the current menu.
0 = User parameter (selection of the visible parameters in
P360)
1 = Parameter menu
2 = Fixed settings (for factory settings)
3 = Quick parameterization (changes to "Drive Setting"
state)
4 = Board configuration (changes to "Board Configuration"
state)
5 = Drive setting (changes to "Drive Setting" state)
6 = Download (changes to "Download" state)
7 = Upread/Free access
8 = Power section definition (changes to "Power section
definition" state)
If it is not possible to change to another state due to the
currently valid state, the corresponding menu cannot be
selected either.
Example:
"Operating" state, change to "Download" not possible.
"Ready for switching on" state, change to "Download"
possible.
With parameters P358 Key and P359 Lock, all menus can
be locked with the exception of the menus "User
parameters" and "Fixed settings".
IMPORTANT: If the parameters Key (P358) or Lock
(P359) are missing in Selection of User Parameters
(P360), a parameterization change is only possible by a
factory setting. The original parameterization is then lost.
Init: 1
Min: 0
Max: 8
Unit: -
Indices: -
Type: O2
Menus:
All menus
Changeable in:
All states
P067
Cool SpecTypes
67
not Compact PLUS
Only for customer-specific special MASTERDRIVES types
of construction.
For future use, not implemented at present!
Init: 0
Min: 0
Max: 1
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
- Upread/free access
- Power section definition
Changeable in:
- Power section definition
r069
SW Version
69
Compact PLUS only
Visualization parameter for displaying the software
versions of the basic board as well as the optional boards
in slots A to G
Index 1: Software version of basic board
Index 2: Software version of optional board Slot A
Index 3: Software version of optional board Slot B
Index 4: Software version of optional board Slot C
Index 5: Software version of optional board Slot D
Index 6: Software version of optional board Slot E
Index 7: Software version of optional board Slot F
Index 8: Software version of optional board Slot G
The slots D-G are not available in type COMPACT PLUS.
For optional boards which contain no software, (e.g. SBR,
SLB), the parameter value in the respective index is
always 0.0.
Dec.Plc.: 1
Unit: -
Indices: 4
Type: O2
Menus:
- Parameter menu
+ General parameters
- Fixed settings
- Quick parameterization
- Board configuration
- Drive setting
- Download
- Upread/free access
- Power section definition
8
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control