Parameter
Description
Data
Read/write
U302*
S.Timer4
2302
BICO parameter for selecting the binector for the 4th timer
(1 to 60,000 s).
Init: 0
Unit: -
Indices: -
Type: L2 ,B
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U303
Time Timer4
2303
Function parameter for entering the time for the 4th timer
(1 to 60,000 s). FDS
index1: 0,000
Min: 0,000
Max: 60,000
Unit: s
Indices: 4
,FDS
Type: O2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U304*
Mode Timer4
2304
Function parameter for entering the mode for the 4th timer
(1 to 600,000 s).
Init: 0
Min: 0
Max: 3
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
U305*
S.Timer5
2305
BICO parameter for selecting the binector for the 5th timer
(0 to 600,000 s).
Init: 0
Unit: -
Indices: -
Type: L2 ,B
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U306
Time Timer5
2306
Function parameter for entering the time for the 5th timer
(0 to 600,000s). FDS
index1: 0,00
Min: 0,00
Max: 600,00
Unit: s
Indices: 4
,FDS
Type: O2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U307*
Mode Timer5
2307
Function parameter for entering the mode for the 5th
timer(0 to 600,000s).
Init: 0
Min: 0
Max: 3
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
U308*
S.Timer6
2308
BICO parameter for selecting the binector for the 6th timer
(0 to 600,000s).
Init: 0
Unit: -
Indices: -
Type: L2 ,B
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U309
Time Timer6
2309
Function parameter for entering the time for the 6th timer
(0 to 600,000s). FDS
index1: 0,00
Min: 0,00
Max: 600,00
Unit: s
Indices: 4
,FDS
Type: O2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U310*
Mode Timer6
2310
Function parameter for entering the mode for the 6th timer
(0 to 600,00s).
Init: 0
Min: 0
Max: 3
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
156
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control