![Siemens simovert masterdrives Compendium Download Page 1181](http://html.mh-extra.com/html/siemens/simovert-masterdrives/simovert-masterdrives_compendium_3781711181.webp)
Parameter
Description
Data
Read/write
P144*
Pulse#MotEnc
144
Input of the encoder pulse number for the motor encoder.
This parameter is active only if P136=0.
P136
0 Use of pulse number parameter for motor control
1 Without function!
Reserved for the use of inverse actual value for motor
control ONLY during installation of the encoder at the
output via a rigid coupling = >
This arrangement serves to increase the stiffness upon
large load inertia and resulting torsion.
Init: 2048
Min: 1
Max: 16000
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Motor/encoder
+ Encoder data
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
P145*
Volts Enc SBM2
145
Setting for the voltage supply of an encoder if an SBM2
board is used.
Index 1: Voltage supply for motor encoder
Index 2: Voltage supply for machine encoder
Irrespective of the parameterization, the maximum voltage
for Compact PLUS units is 19 V and for Compact units 15
V.
The value is entered in Volts.
index1: 5
Min: 5
Max: 25
Unit: -
Indices: 2
Type: O2
Menus:
- Parameter menu
+ Motor/encoder
+ Encoder data
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
P146*
ZeroPt Displace
146
Setting of zero point offset on multiturn absolute-value
encoders.
The zero point offset is entered in revolutions on the
motor encoder and in increments on the external encoder.
Index 1: Offset for motor encoder (in revolutions)
Index 2: Offset for external encoder (in increments)
index1: 0
Min: -
2147483647
Max:
2147483647
Unit: -
Indices: 2
Type: I4
Menus:
- Parameter menu
+ Motor/encoder
+ Encoder data
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
P147*
SelectMultiturn
147
Function parameter for entering the type of encoder.
Setting is performed in the "Drive settings" menu and it
configures the interface to a multiturn encoder.
Index 1 Selection of the multiturn encoder as a motor
encoder.
Index 2 Selection of the multiturn encoder as an external
encoder.
This parameter carries out all the necessary settings for
standard encoders and overwrites the parameters P148
and P149. On every change of P147, parameters P148
and P149 are pre-assigned with the settings for the type
of encoder selected.
0: No standard encoder => Parameterization in P148 and
P149 by the user
1: EQN1325 (Messrs. Heidenhain)
2: ECN1313 (Messrs. Heidenhain)
3: SSI 25bit (Messrs. FRABA/Stegmann/TR/TWK etc)
4: SSI 21bit (Messrs. FRABA/Stegmann/TR/TWK etc)
5: SSI 13bit (Messrs. FRABA/Stegmann/TR/TWK etc)
6: EnDat (Messrs. Heidenhain), data are read out of
the encoder, e.g. LC181 linear scale.
7: EQI1325 (Messrs. Heidenhain)
8: EQN1125 (Messrs. Heidenhain) - only for motor
encoder
9: ECN1113 (Messrs. Heidenhain) - only for motor encoder
index1: ~
Min: 0
Max: 15
Unit: -
Indices: 2
Type: O2
Menus:
- Parameter menu
+ Motor/encoder
+ Encoder data
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
21
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control