Parameter
Description
Data
Read/write
U818*
BasicRFG1 LU
2818
Parameter input LU for 1st basic ramp generator (32 bit)
Index 1: Upper limit
Index 2: Lower limit
Index 3: Fixed setpoint setting value
[Function diagram 786a]
index1:
2147483647
Min: -
2147483647
Max:
2147483647
Unit: -
Indices: 3
Type: I4
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U819*
S.AddDispEnable
2819
Binector source for positioning enable
[Function diagram 794]
Init: 1
Unit: -
Indices: -
Type: L2 ,B
Menus:
- Parameter menu
+ Setpoint channel
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U820*
AddDispl ACL
2820
The axis cycle length is entered here that the
sychnonization block receives at the input. For example,
the axis cycle length of the virtual master axis U687 or of
the real master U425.1. In contrast, zero is entered for a
linear axis.
Init: 4096
Min: 0
Max:
2147483647
Unit: -
Indices: -
Type: I4
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
U821*
S.Add.DisplAngle
2821
Source for displacement angle
Index 1: Input of additive relative displacement angle
Index 2: Set input of additive displacement angle
Index 3: Input of absolute displacement angle
index1: 0
Unit: -
Indices: 3
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U822*
S.AddDisplTrig
2822
Index 1: 0->1 Increase displacement angle
Index 2: 0->1 Decrease displacement angle
Index 3: 0 ->1 Inch + displacement angle
Index 4: 0 ->1 Inch - displacement angle
index1: 0
Unit: -
Indices: 4
Type: L2 ,B
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U823*
AddDisplMode
2823
U823.01 (0)
0 = Displacement is processed as absolute
1 = Displacement is processed with residual-displacement
evaluation.
U823.02 (1)
0 = Shortest path
1 = As specified (new value > old value => pos. direction)
index1: 0
Min: 0
Max: 1
Unit: -
Indices: 2
Type: O2
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
U824*
S.AddDispV-fac
2824
INDEX 1:
Speed adjustment in percent for U825.2
INDEX 2:
Speed adjustment in percent for U825.4
index1: 1
Unit: -
Indices: 2
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Free blocks
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
236
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control