Function diagram
8
7
6
5
4
3
2
1
fp_mc_172a_e.vsd
Communication
MASTERDRIVES MC
07.01.02
Encoder interface DP V3 encoder 1 (motor encoder)
- 172a -
V2.5
BD1
SD12
Parking
SD3
Fault
SD2
Fault acknowledgement
SD1
Normal operation
SD11
Measured value in
XIST2
SD10
Wait for measured
value
SD4
Reference value in
XIST2
SD5
Wait for reference mark
SD6
Check reference task
SD7
Set/shift reference point
executed
SD8
Absolute value
cyclically in XIST2
SD9
Check measuring task
PROFIDrive DPV3 encoder interface
Encoder 1 Pos ActV 2
G1_XIST2
[G1_STW]
.1
Pos ActV G1 (KK0120)
PosMeasV G1 (KK0122)
RefValue G1 (KK0124)
.1
Ackn RefPoint G1 (B0210)
Ackn MeasV G1 (B0212)
.1
Encoder 1 status word
G1_ZSW
Src sensing probe 1 (B0016)
Src sensing probe 2 (B0018)
<3>
<1>
<1>
<2> <4>
P645.2 [90.7]
P649.2 [90.7]
P173 [330.5]
P177 [330.5]
<4>
P178 [335.5]
P179 [330.5]
P645.1 [90.7]
P649.1 [90.7]
G1_STW
Motor
encoder
Conf DigIn 4/5
Ref.only zero pulse
Src MeasV valid G1 (B0070)
<6>
<1> Only possible for encoder 1 (motor encoder)!
<2> The reference point (setting/shifting) will either be
permanently specified in the unit, or transferred via
an additional channel from the master.
<3> In the event of a fault the fault value will be active in
Gx_XIST2
1 = Encoder sum error
2 = Zero mark monitoring
4 = Terminate reference mark search
5 = Terminate collect reference value
6 = Terminate flying measurement
7 = Terminate collect measured value
8 = Terminate absolute value transmission on
A = Error in reading absolute track of the absolute
value encoder (EnDat-encoder)
<4> The reference value is shifted, for example, via an
analog switch which acts on the position offset of
the respective encoder.
<5> Trigger rough pulse
For referencing with zero pulse only, the rough
pulse (P178) is set to 1 for one cycle in state SD6.
Only possible for encoder 1 (motor encoder)!
<6> Measured value valid must be 1, otherwise a fault
message will be tripped (exception: No fault
message is activated if B70 is missing in states
SD1, SD7 and SD12).
U953.64 = ___(20)
Status G1(SDx)
n924.1
KK0912
B0928
Fault acknowledgement MC
G1_ZSW
n925 [HEX]
KK (0)
.3
KK (0)
.5
B (212)
.3
B0918
Enable reference point detection mot. encoder
B0920
Set motor encoder reference point
B0922
Shift motor encoder reference point
B0926
DigIn 4 rising/falling edge
B0927
DigIn 5 rising/falling edge
B (16)
.5
B (18)
.6
G1_XIST2
n927 [HEX]
B0931
Trigger rough pulse mot.enocder <5>
B0924
Enable motor measured value memory
B0929
DigIn 4 Enable <1>
B0930
DigIn 5 Enable <1>
B (70)
.7
KK (0)
U922
Encoder ActV
B (210)
U923
Encoder checkback
K (0)
U921
Encoder control word
K0910
B0911
Bit 1: Function2
B0910
Bit 0: Function1
B0912
Bit 2: Function3
B0913
Bit 3: Function4