2
Fault list – safety technology
Fault 70 Safe brake system
Manual – Fault Descriptions MOVISAFE
®
CS..A
93
Subfault: 70.16
Description: Safe brake test aborted. Fault in effective direction of test torque.
Fault class: Warning
Cause
Measure
The torque specified by the basic unit has the
wrong effective direction.
– Check the settings of the basic unit and adjust,
if necessary.
– Check the settings for direction of rotation re-
versal and adjust, if necessary.
Subfault: 70.18
Description: Safe brake test aborted. Error, error acknowledgment.
Fault class: System error
Cause
Measure
Fault acknowledged during safe brake test.
Deactivate the safe brake test before acknowled-
ging the fault.
Subfault: 70.19
Description: Safe brake test aborted. Drive safety function signals limit violation.
Fault class: Warning
Cause
Measure
Limit violation signaled by drive safety function
active at the same time (e.g. SLS) during safe
brake test.
– Check which drive safety function signaled the
limit violation.
– Refer to the measures in the fault description to
eliminate the fault.
Subfault: 70.20
Description: Safe brake test aborted. Safety card fault.
Fault class: Warning
Cause
Measure
Fault detected by safety card during safe brake
test.
– Check which fault has occurred.
– Refer to the measures in the fault description to
eliminate the fault.
Subfault: 70.22
Description: Safe brake test aborted. Fault while checking load torque.
Fault class: Warning
Cause
Measure
Failed to check load torque while executing safe
brake test. Cannot determine load torque.
– Extend the duration of the individual test steps.
– Deactivate load torque checking (load
torque = 0).
27799182/EN – 10/2022