2
Fault list – safety technology
Fault 60 Safe digital input
Manual – Fault Descriptions MOVISAFE
®
CS..A
41
Subfault: 60.33
Description: F-DI 01 Crossfault
Fault class: Input fault
Cause
Measure
Crossfault detected at safe digital input F-DI 01 or
plausibility test failed.
– Check the external wiring/connection of safe
digital input F‑DI 01 for crossfault.
– Acknowledge the fault.
Subfault: 60.34
Description: F-DI 02 Crossfault
Fault class: Input fault
Cause
Measure
Crossfault detected at safe digital input F-DI 02 or
plausibility test failed.
– Check the external wiring/connection of safe
digital input F‑DI 02 for crossfault.
– Acknowledge the fault.
Subfault: 60.35
Description: F-DI 03 Crossfault
Fault class: Input fault
Cause
Measure
Crossfault detected at safe digital input F-DI 03 or
plausibility test failed.
– Check the external wiring/connection of safe
digital input F‑DI 03 for crossfault.
– Acknowledge the fault.
Subfault: 60.40
Description: F-DI 00 Connection error
Fault class: Input fault
Cause
Measure
Maximum response time exceeded at safe digital
input F‑DI 00. No stable input signal at F‑DI 00
within the parameterized input filter time.
– Check the switch/sensor connected to safe digi-
tal input F‑DI 00.
– Increase the parameter "Input filter time" at
F‑DI 00.
– Acknowledge the fault.
Subfault: 60.41
Description: F-DI 01 Connection error
Fault class: Input fault
Cause
Measure
Maximum response time exceeded at safe digital
input F‑DI 01. No stable input signal at F‑DI 01
within the parameterized input filter time.
– Check the switch/sensor connected to safe digi-
tal input F‑DI 01.
– Increase the parameter "Input filter time" at
F‑DI 01.
– Acknowledge the fault.
27799182/EN – 10/2022