Fault list – safety technology
Fault 70 Safe brake system
Manual – Fault Descriptions MOVISAFE
®
CS..A
92
Subfault: 70.12
Description: Safe brake test aborted. Error, assignment of drive safety function SBC.
Fault class: Warning
Cause
Measure
SBC drive safety function not assigned to safe
digital output F‑DO.
– Check the parameter setting of the safety card.
– Assign the SBC drive safety function to one of
the safe digital outputs F‑DO and connect the
brake control (e.g. BST) to it.
Subfault: 70.13
Description: Safe brake test aborted. Error, movement during idle state.
Fault class: Warning
Cause
Measure
Maximum movement permitted at idle state ex-
ceeded.
Brake or basic unit cannot hold the load torque.
– Check
Permitted movement during idle state
parameter and correct, if necessary.
– Make sure that the brake control is correct.
– Make sure that the basic unit provides the re-
quired power.
– Make sure that the brake can hold the load
torque and the test torque.
Subfault: 70.14
Description: Safe brake test aborted. Minimum speed fault.
Fault class: Warning
Cause
Measure
Speed greater than parameterized minimum
speed detected at end of retraction distance.
– Check the settings of the safety card and ad-
just, if necessary.
– Check the settings of the basic unit and adjust,
if necessary.
– Make sure that the basic unit is not subject to
overload.
Subfault: 70.15
Description: Safe brake test aborted. Minimum speed fault.
Fault class: Warning
Cause
Measure
Speed greater than parameterized minimum
speed detected when activating brake test.
Check the minimum speed and adjust, if neces-
sary.
27799182/EN – 10/2022