2
Fault list – safety technology
Fault 64 Position-dependent drive safety functions
Manual – Fault Descriptions MOVISAFE
®
CS..A
59
2.13
Fault 64 Position-dependent drive safety functions
Subfault: 64.1
Description: SDI 1 limit position exceeded in blocked direction of movement
Fault class: Warning
Cause
Measure
SDI 1 limit position exceeded in blocked direction
of movement.
– Check the direction of movement of the applica-
tion while the drive safety function is active, and
adjust if necessary.
– Check the parameter setting of the safety card
(permitted direction of movement SDI 1, tolerance
SDI 1) and adjust if necessary.
Subfault: 64.2
Description: SDI 2 limit position exceeded in blocked direction of movement
Fault class: Warning
Cause
Measure
SDI 2 limit position exceeded in blocked direction
of movement.
– Check the direction of movement of the applica-
tion while the drive safety function is active, and
adjust if necessary.
– Check the parameter setting of the safety card
(permitted direction of movement SDI 2, tolerance
SDI 2) and adjust if necessary.
Subfault: 64.5
Description: SLI 1 limit position exceeded in positive direction of movement
Fault class: Warning
Cause
Measure
SLI 1 limit position exceeded in positive direction
of movement.
Check the parameter setting of the safety card
(position tolerance SLI 1), and adjust if neces-
sary.
Subfault: 64.6
Description: SLI 2 limit position exceeded in positive direction of movement
Fault class: Warning
Cause
Measure
SLI 2 limit position exceeded in positive direction
of movement.
Check the parameter setting of the safety card
(position tolerance SLI 2), and adjust if neces-
sary.
27799182/EN – 10/2022