2
Fault list – safety technology
Fault 66 Safety-related fault
Manual – Fault Descriptions MOVISAFE
®
CS..A
73
Subfault: 66.80
Description: Change of process data bit "cam slip adjustment" at wrong position
Response: FS – warning
Cause
Measure
The process data bit "slip adjustment cam"
changed the state at a position where no slip ad-
justment cam was configured.
– Check the parameter setting of the slip com-
pensation.
– Check the generation of process data in the
controller.
Subfault: 66.81
Description: Maximum distance slip adjustment exceeded
Response: FS – warning
Cause
Measure
Parameterized distance exceed without having
performed slip adjustment or referencing.
– Allow slip adjustment cams to be passed over
more frequently.
– Parameterize a longer distance.
Subfault: 66.89
Description: Two SREF functions activated at the same time
Response: FS – warning
Cause
Measure
Two SREF functions activated at the same time.
Perform a new referencing.
Subfault: 66.90
Description: Acknowledgment missing for restart
Fault class: System error
Cause
Measure
Acknowledging message required for restart.
Acknowledge the safety card.
Subfault: 66.91
Description: Parameter setting with non-acknowledged fault
Fault class: System error
Cause
Measure
Parameterization or validation performed while
fault is pending.
Acknowledge the error.
27799182/EN – 10/2022