2
Fault list – safety technology
Fault 63 Speed-dependent drive safety function
Manual – Fault Descriptions MOVISAFE
®
CS..A
56
Subfault: 63.33
Description: SSx maximum speed exceeded in positive direction of movement
Fault class: Warning
Cause
Measure
SSx maximum speed exceeded in positive direc-
tion of movement during monitoring delay.
– Check the maximum speed of the application
while the drive safety function is active, and ad-
just if necessary.
– Check the parameter setting of the safety card
(maximum speed), and adjust if necessary.
Subfault: 63.41
Description: SSx maximum speed exceeded in negative direction of movement
Fault class: Warning
Cause
Measure
SSx maximum speed exceeded in negative direc-
tion of movement during monitoring delay.
– Check the maximum speed of the application
while the drive safety function is active, and ad-
just if necessary.
– Check the parameter setting of the safety card
(maximum speed), and adjust if necessary.
Subfault: 63.49
Description: SSx 1 limit speed exceeded in positive direction of movement during deceleration
Fault class: Warning
Cause
Measure
SSx 1 limit speed exceeded in positive direction
of movement during deceleration.
– Check deceleration, jerk time, and ramp type of
the application while the drive safety function is
active, and adjust if necessary.
– Check the parameter setting of the safety card
(deceleration SSx 1, jerk time SSx 1, ramp type
SSx 1), and adjust if necessary.
Subfault: 63.50
Description: SSx 2 limit speed exceeded in positive direction of movement during deceleration
Fault class: Warning
Cause
Measure
SSx 2 limit speed exceeded in positive direction
of movement during deceleration.
– Check deceleration, jerk time, and ramp type of
the application while the drive safety function is
active, and adjust if necessary.
– Check the parameter setting of the safety card
(deceleration SSx 2, jerk time SSx 2, ramp type
SSx 2), and adjust if necessary.
27799182/EN – 10/2022