Fault list – safety technology
Fault 64 Position-dependent drive safety functions
Manual – Fault Descriptions MOVISAFE
®
CS..A
63
Subfault: 64.42
Description: SLP 2 limit position exceeded
Response: FS – warning
Cause
Measure
Limit position SLP exceeded.
Deactivate the SLP drive safety function before
acknowledging the fault. Set the SLP limit posi-
tion in the valid range. Activate the SLP drive
safety function again.
Subfault: 64.45
Description: SLP 1 limit speed exceeded in positive direction of movement
Response: FS – warning
Cause
Measure
SLP speed not reduced or not reduced fast
enough when approaching limit position.
Deactivate the SLP drive safety function before
acknowledging the fault. Reduce the SLP speed.
Activate the SLP drive safety function again.
Subfault: 64.46
Description: SLP 2 limit speed exceeded in positive direction of movement
Response: FS – warning
Cause
Measure
SLP speed not reduced or not reduced fast
enough when approaching limit position.
Deactivate the SLP drive safety function before
acknowledging the fault. Reduce the SLP speed.
Activate the SLP drive safety function again.
Subfault: 64.49
Description: SLP 1 limit speed exceeded in negative direction of movement
Response: FS – warning
Cause
Measure
SLP speed not reduced or not reduced fast
enough when approaching limit position.
Deactivate the SLP drive safety function before
acknowledging the fault. Reduce the SLP speed.
Activate the SLP drive safety function again.
Subfault: 64.50
Description: SLP 2 limit speed exceeded in negative direction of movement
Response: FS – warning
Cause
Measure
SLP speed not reduced or not reduced fast
enough when approaching limit position.
Deactivate the SLP drive safety function before
acknowledging the fault. Reduce the SLP speed.
Activate the SLP drive safety function again.