2
Fault list – safety technology
Fault 14 Encoder 2
Manual – Fault Descriptions MOVISAFE
®
CS..A
17
Subfault: 14.52
Description: Encoder signal fault
Response: FS – warning
Cause
Measure
Unexpected encoder signals.
– Check the wiring.
– Check interference sources.
– Apply the shield of the encoder cable over a
large area.
– Check the encoder.
Subfault: 14.53
Description: Maximum frequency exceeded
Response: FS – warning
Cause
Measure
Maximum permitted signal frequency exceeded.
– Check the maximum input frequency.
– Check the wiring.
– Check interference sources.
– Apply the shield of the encoder cable over a
large area.
– Check the encoder.
Subfault: 14.54
Description: Cross comparison error
Response: FS – warning
Cause
Measure
Cross comparison error in encoder evaluation.
– Check the wiring.
– Check interference sources.
– Apply the shield of the encoder cable over a
large area.
– Check the encoder.
Subfault: 14.55
Description: Signal level monitoring
Response: FS – warning
Cause
Measure
Track signal level not within tolerance band.
– Check the wiring.
– Check interference sources.
– Apply the shield of the encoder cable over a
large area.
– Check the encoder.
27799182/EN – 10/2022