2
Fault list – safety technology
Fault 61 Safe digital output
Manual – Fault Descriptions MOVISAFE
®
CS..A
42
Subfault: 60.42
Description: F-DI 02 Connection error
Fault class: Input fault
Cause
Measure
Maximum response time exceeded at safe digital
input F‑DI 02. No stable input signal at F‑DI 02
within the parameterized input filter time.
– Check the switch/sensor connected to safe digi-
tal input F‑DI 02.
– Increase the parameter "Input filter time" at
F‑DI 02.
– Acknowledge the fault.
Subfault: 60.43
Description: F-DI 03 Connection error
Fault class: Input fault
Cause
Measure
Maximum response time exceeded at safe digital
input F‑DI 03. No stable input signal at F‑DI 03
within the parameterized input filter time.
– Check the switch/sensor connected to safe digi-
tal input F‑DI 03.
– Increase the parameter "Input filter time" at
F‑DI 03.
– Acknowledge the fault.
2.10
Fault 61 Safe digital output
Subfault: 61.1
Description: F-DO 00 Internal fault
Fault class: Output fault
Cause
Measure
Fault in safe digital output F-DO 00 detected on
safety card during internal test of safe digital out-
put channels.
– Acknowledge the fault.
– If the fault occurs repeatedly, replace the safety
card and send it together with the fault number to
SEW‑EURODRIVE. For further support, contact
SEW‑EURODRIVE Service.
Subfault: 61.2
Description: F-DO 01 Internal fault
Fault class: Output fault
Cause
Measure
Fault in safe digital output F-DO 01 detected on
safety card during internal test of safe digital out-
put channels.
– Acknowledge the fault.
– If the fault occurs repeatedly, replace the safety
card and send it together with the fault number to
SEW‑EURODRIVE. For further support, contact
SEW‑EURODRIVE Service.
27799182/EN – 10/2022