2
Fault list – safety technology
Fault 60 Safe digital input
Manual – Fault Descriptions MOVISAFE
®
CS..A
40
Subfault: 60.20
Description: FD-I Internal fault
Fault class: Input fault
Cause
Measure
Fault detected on safety card during internal test
of safe digital inputs F-DI.
– Acknowledge the fault.
– If the fault occurs repeatedly, replace the safety
card and send it together with the fault number to
SEW‑EURODRIVE. For further support, contact
SEW‑EURODRIVE Service.
Subfault: 60.22
Description: F-DI 00/01 Discrepancy error
Fault class: Input fault
Cause
Measure
Discrepancy error F‑DI 00/01:
– The parameterized discrepancy time in 2-chan-
nel evaluation of the safe digital inputs F‑DI 00/01
has been exceeded, or an error has been detect-
ed in a subchannel.
– Switch test condition not fulfilled.
– Check the 2-channel switch/sensor connected
to the safe digital input pair F‑DI 00/01.
– Check the parameter setting of the safety card.
If necessary, increase the discrepancy time.
– If the switch test function at F‑DI 00/01 is active,
make sure that the switch test condition is fulfilled
before acknowledging the fault.
– Acknowledge the fault.
Subfault: 60.24
Description: F-DI 02/03 Discrepancy error
Fault class: Input fault
Cause
Measure
Discrepancy error F‑DI 02/03:
– The parameterized discrepancy time in 2-chan-
nel evaluation of the safe digital inputs F‑DI 02/03
has been exceeded, or an error has been detect-
ed in a subchannel.
– Switch test condition not fulfilled.
– Check the 2-channel switch/sensor connected
to the safe digital input pair F‑DI 02/03.
– Check the parameter setting of the safety card.
If necessary, increase the discrepancy time.
– If the switch test function at F‑DI 02/03 is active,
make sure that the switch test condition is fulfilled
before acknowledging the fault.
– Acknowledge the fault.
Subfault: 60.32
Description: F-DI 00 Crossfault
Fault class: Input fault
Cause
Measure
Crossfault detected at safe digital input F-DI 00 or
plausibility test failed.
– Check the external wiring/connection of safe
digital input F‑DI 00 for crossfault.
– Acknowledge the fault.
27799182/EN – 10/2022