2
Fault list – safety technology
Fault 13 Encoder 1
Manual – Fault Descriptions MOVISAFE
®
CS..A
7
Subfault: 13.21
Description: SSI encoder – fault
Response: FS – warning
Cause
Measure
SSI encoder detected a fault.
– Check the startup parameters.
– Check the settings on the SSI encoder.
– Check the wiring.
– Check interference sources (light beam inter-
rupted, reflector, data cables, etc.).
– Replace the encoder.
INFORMATION
In "Emergency mode" manual mode, you can
move the drive even with a faulty external posi-
tion encoder.
Subfault: 13.23
Description: Internal fault
Response: FS – warning
Cause
Measure
Encoder signaled internal fault.
INFORMATION
The encoder fault code is displayed in
MOVISUITE
®
in the [Diagnostics] > [Fault
memory T.] parameter group in the "Internal" pa-
rameter.
– Check the wiring.
– Check interference sources (light beam inter-
rupted, reflector, data cables, etc.).
– Replace the encoder.
INFORMATION
In "Emergency mode" manual mode, you can
move the drive using the motor encoder even if
the external position encoder is faulty.
Subfault: 13.50
Description: Safety card encoder fault
Response: FS – encoder fault
Cause
Measure
Encoder fault detected on safety card.
– Check the wiring.
– Check interference sources.
– Apply the shield of the encoder cable over a
large area.
– Check the encoder.
27799182/EN – 10/2022