2
Fault list – safety technology
Fault 63 Speed-dependent drive safety function
Manual – Fault Descriptions MOVISAFE
®
CS..A
58
Subfault: 63.69
Description: SSR 1 lower limit speed exceeded
Fault class: Warning
Cause
Measure
SSR 1 lower speed exceeded.
– Check the speed setpoint of the application
while the drive safety function is active, and ad-
just if necessary.
– Check the parameter setting of the safety card
(lower limit speed SSR 1), and adjust if neces-
sary.
Subfault: 63.70
Description: SSR 2 lower limit speed exceeded
Fault class: Warning
Cause
Measure
SSR 2 lower speed exceeded.
– Check the speed setpoint of the application
while the drive safety function is active, and ad-
just if necessary.
– Check the parameter setting of the safety card
(lower limit speed SSR 2), and adjust if neces-
sary.
Subfault: 63.73
Description: SSR maximum speed exceeded in positive direction of movement
Fault class: Warning
Cause
Measure
SSR maximum speed exceeded in positive direc-
tion of movement during monitoring delay.
– Check the maximum speed of the application
while the drive safety function is active, and ad-
just if necessary.
– Check the parameter setting of the safety card
(maximum speed), and adjust if necessary.
Subfault: 63.74
Description: SSR maximum speed exceeded in negative direction of movement
Fault class: Warning
Cause
Measure
SSR maximum speed exceeded in negative di-
rection of movement during monitoring delay.
– Check the maximum speed of the application
while the drive safety function is active, and ad-
just if necessary.
– Check the parameter setting of the safety card
(maximum speed), and adjust if necessary.
27799182/EN – 10/2022